EasyManua.ls Logo

Kohler K-3492 - Page 5

Kohler K-3492
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting Guide (cont.)
Symptoms Probable Causes Recommended Action
3. The toilet fails to operate. A. There is a problem with the
wiring.
A. Check the wiring and connect the
power.
B. The GFCI or ELCB is tripped. B. Reset the GFCI or ELCB (if
applicable).
C. There is a problem with the
pump connection.
C. Check the pump connection.
D. The actuation switch is not
properly connected.
D. Check the actuation switch
connection.
E. The level switch is not properly
connected.
E. Check the level switch connection.
F. The pump assembly does not
work.
F. Replace the pump assembly.
G. The actuation assembly does not
work.
G. Replace the actuation assembly.
Kohler Co. 5 1035530-5-D

Other manuals for Kohler K-3492