Page #12 background imageLoading...
Page #12 background image
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
H. Bleed hole in the
diaphragm is
plugged or debris
exists on the seal.
H. Remove the spout
body. Clean or replace
the diaphragm.
I. Wires are pinched
or damaged.
I. Check the wires for
damage. Verify the
wires are tucked inside
the spout. Replace the
assembly with damaged
wires if needed.
J. There is a loose
connection.
J. Check the solenoid
and sensor connections.
Confirm the arrows are
aligned and connections
are secure.
K. There is water
leaking internally.
K. Determine the cause
of the leak. Check for
corrosion on
connections. Inspect the
valve O-ring for
damage. Replace if
needed. Clean the
terminals. Replace
damaged parts.
L. Solenoid is not
working.
L. Install a new
solenoid service kit.
3. Low flow. A. Filter is plugged. A. Clean or replace the
filters.
B. Supply pressure is
low.
B. Check incoming
water pressure. Pressure
should be at least 20 psi
(137 kPa).
C. Aerator is
plugged.
C. Remove the aerator
and clean it. For
calcium/mineral
deposits, soak the
aerator plastic insert in
a 50:50 mixture of
vinegar and water. Soak
only the insert and no
other components.
1244026-5-A 12 Kohler Co.

Other manuals for Kohler K-7514

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler K-7514 and is the answer not in the manual?

Kohler K-7514 Specifications

General IconGeneral
BrandKohler
ModelK-7514
CategoryPlumbing Product
LanguageEnglish

Related product manuals