8.4 Specifications
DIESEL 10 LC A
SILENCE C5
DIESEL 10 LC A
SILENCE AVR C5
DIESEL 15 LC TA
SILENCE C5
DIESEL 15 LC TA
SILENCE AVR C5
Acoustic measurement uncertainty
2x2P+T-230V-10/16A
+ 1x2P+T-230V-16A
+ 1x2P+T-230V-32A
2x2P+T-230V-10/16A
+ 1x2P+T-230V-16A +
1x2P+T-230V-32A
1x2P+T-230V-10/16A
+ 3x2P+T-230V-16A +
1x2P+T-400V-16A
1x2P+T-230V-
10/16A + 3x2P+T-
230V-16A +
1x2P+T-400V-16A
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal switches that may be equipped with differential
protection. In the event of an overload and/or short circuit, the power supply may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
8.5 Recommended fuel quality
Using fuel which does not comply with the following specifications risks causing irreversible damage not covered under the warranty:
- Cleanliness and quality: ensure that the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
- Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
- Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).
However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.
8.6 EC Declaration of conformity
We, SDMO Industries - 270 rue de Kerervern, 29490 GUIPAVAS/CS 40047, 29801 BREST CEDEX 9 – France, hereby declare
under our sole responsibility that the following generating sets:
DIESEL 10 LC A SILENCE C5
DIESEL 10 LC A SILENCE AVR C5
DIESEL 15 LC TA SILENCE C5
DIESEL 15 LC TA SILENCE AVR C5
25-2021-00000000-000
52-2026-99999999-999
1. Comply with the safety requirements set out in the Low Voltage Directive - 2014/35/EU of 26 February 2014 in application of the
harmonized standard EN 60204-1: 2006 (AMD 1 2006, COR 2010)
2. Comply with the provisions of the following Directives:
- Machinery - 2006/42/EC of 17th May 2006 in application of the harmonized standard EN 8528:-13 2016
- Electromagnetic compatibility - 2014/30/EU of 26th February 2014 in application of the harmonized standards EN 60034-1:
2010 (COR 2010) / EN 61000-6-1: 2007 / EN 61000-6-2: 2005 (COR 2005) / EN 61000-6-3: 2007 (AMD1 2011,
AMD1/COR 12) / EN 55011: 2009 (AMD 1 2010)
- Relating to the restriction of the use of certain hazardous substances in electrical and electronic equipment - 2011/65/EU of
8th June 2011 in application of the harmonized standard EN IEC 63000 : 2018.
- Relating to noise emission in the environment by equipment for use outdoors- 2000/14/EC of 8 May 2000, via the
compliance procedure set out in Annex VI:
Measured sound
power level:
Guaranteed sound
power level (LwA):
DIESEL 10 LC A SILENCE C5
DIESEL 10 LC A SILENCE AVR C5
DIESEL 15 LC TA SILENCE C5
CETIM - BP
67- F60304 –
SENLIS -
FRANCE
DIESEL 15 LC TA SILENCE AVR C5
Name and address of the person authorized to create and hold the technical file:
L. ANDRIEUX, 270 rue de Kerervern, 29490 GUIPAVAS / CS 40047, 29801 BREST CEDEX 9 – France.
President, SDMO Industries