Auto Reset High Pump Switch:
If the High Pump Switch trips, H.P” is displayed until
the failure clears. Once failure clears, the unit goes back
to the previous mode it was in before the trip. If the High
Pump Switch trips 3 times within 30 minutes, the unit
is locked out, forced into the O position, and “E.H” is
displayed and Power LED will blink, signaling that the
alarm condition is present. Once the failure is cleared,
the room temperature will display and pressing any mode
button can manually reactivate the unit.
Optional Remote Control:
e optional remote control has identical functions as the
main unit excluding the following:
Ability to change the “temperature dierential” setting.
User can only adjust such setting through the main unit
panel.
Ability to enable or disable the “self recovery mode” set-
ting. User can only adjust such setting through the main
unit panel.
User is only allowed to change setting when unit is OFF