Questions and Answers

  • E
    Elijah GonzalesAug 11, 2025
    Why does my Kolmeks FC stop by itself or run irregular and noisy?
    • N
      nacostaAug 11, 2025
      If your Kolmeks Water Pump stops by itself or runs irregularly and noisily, it could be due to a defective supply voltage, which requires checking. Another possibility is a missing phase, in which case you should check and repair fuses and cable connections. In some instances, the frequency converter or electric motor might be damaged, necessitating replacement.
  • J
    jessica48Aug 16, 2025
    How to fix a noisy Kolmeks FC Water Pump?
    • M
      Mark CordovaAug 16, 2025
      If your Kolmeks Water Pump is noisy, it could be due to cavitation, which can be addressed by increasing the suction pressure. Alternatively, the pump's pressure difference might be too high, requiring a decrease in flow. A faulty shaft seal or bearings could also be the cause, necessitating replacement. Electrical noise from the frequency converter or electric motor might also contribute; if necessary, correct the parameters of the frequency converter.
  • M
    marioolsonAug 20, 2025
    What to do if my Kolmeks FC Water Pump is not pumping?
    • M
      medinajosephAug 20, 2025
      If your Kolmeks Water Pump is not pumping, it could be due to air in the pump or system, which requires deaeration. Alternatively, the suction pressure may be too low, requiring an increase. Another possibility is that circulation is closed off by the valves; ensure the valves are open.
  • J
    Julie MarshAug 25, 2025
    Why is my Kolmeks Water Pump running at maximum frequency without flow changes?
    • A
      April RobinsonAug 25, 2025
      If your Kolmeks Water Pump is running only with the maximum frequency, which doesn’t vary in accordance with the requirements of flow changes, the reference signal might be too high. If you intend to use the potentiometer as the source of reference, adjust the value accordingly. Another possibility is that the feedback transmitter is missing or the signal is wrong, so check and repair the feedback signal and/or connections. The pipes of the pressure or differential pressure transducer may also be blocked or incorrectly connected; in this case, check and repair the connections and blockings of the pipes.
  • A
    Amy FosterSep 2, 2025
    How to fix a leaking shaft seal on a Kolmeks FC Water Pump?
    • M
      Mrs. Catherine OrtizSep 2, 2025
      If the shaft seal of your Kolmeks Water Pump is leaking, it is likely due to wearing or the pump having run dry. The suggested solution is to change the seal.
  • S
    sheilamendozaNov 6, 2025
    What to do if my Kolmeks Water Pump doesn't run?
    • M
      Monica JohnsonNov 6, 2025
      If your Kolmeks Water Pump isn't running, several factors could be at play. The pump shaft might be blocked, so check its free rotation by turning the motor fan. Fuses may have blown, requiring replacement. There might be no electricity reaching the pump; try resetting it by disconnecting the supply voltage for at least 10 seconds. An existing disorder could have stopped the pump, necessitating repair. Incorrect control wiring could be the issue, so verify the wiring against the control diagram. The frequency converter parameters might be altered, or the pump could be stopped via a local control panel; correct the parameters or use the local control panel to restart the pump. In some cases, the frequency converter or electric motor could be damaged, requiring replacement. If these steps do...
  • M
    mathewgonzalezDec 1, 2025
    Why is my Kolmeks Water Pump running at minimum frequency?
    • M
      mercadoglennDec 1, 2025
      If your Kolmeks Water Pump is running with minimum frequency, the reference value might be missing or at a minimum. Adjust the correct value with the potentiometer if you intend to use it as the source of the reference signal. The pipes of the pressure or differential pressure transducer may be blocked or incorrectly connected; check and repair the connections and blockings of the pipes. The signal of the feedback transmitter (pressure or temperature) might be too high; disconnect the cable from the transmitter to see if the speed increases, indicating a fault in the transmitter or the signal. A short circuit is also possible; check and repair the connections or the transmitter. The mechanical or electrical connections of the temperature transmitter of the FCF-pump could be incorrect, or t...