EasyManua.ls Logo

Kolver EDU1FR/SG - User Manual

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Vers. 080920
DICHIARAZIONE DI CONFORMITA’/
DECLARATION OF CONFORMITY
KOLVER S.r.l.
VIA MARCO CORNER, 19/21
36016 THIENE (VI) ITALIA
Dichiara che la macchina nuova qui descritta/ Declare that the new tool here described:
Avvitatore elettrico e unità di controllo/ Electric screwdriver and control unit:
FAB03SS/FR
110003/FR
RAF32NS/FR
120032/FR
FAB10RE/FR
110010/FR
RAF32PS/FR
122032/FR
FAB12RE/FR
110012/FR
RAF32PP/FR
120033/FR
FAB12PS/FR
112012/FR
RAF32PP/FR/U
120033/FR/U
FAB12PP/FR
110013/FR
RAF38NS/FR
120638/FR
FAB12PP/FR/U
110013/FR/U
RAF38PS/FR
122638/FR
FAB18RE/FR
110618/FR
RAF38PP/FR
120639/FR
FAB18PS/FR
112618/FR
RAF38PP/FR/U
120639/FR/U
FAB18PP/FR
110619/FR
RAF50NS/FR
120650/FR
FAB18PP/FR/U
110619/FR/U
RAF50PS/FR
122650/FR
RAF50PP/FR
120651/FR
RAF50PP/FR/U
120651/FR/U
EDU1FR
010010/FR
EDU1FR/SG
010010/FR/SG
È conforme alle disposizioni legislative che traspongono le direttive e le normative/ Is in
conformity with the following standards and other normative documents:
2006/42/CE, LVD 2014/35/UE, EMCD 2014/30/UE, EN 62841-2-2:2014,
EN 62841-1: 2015, EN 60204-1, EN 61000-6-2, EN 61000-6-4.
È conforme alla direttiva RoHS III (2011/65/UE e successiva 2015/863)/ It is also in
conformity with RoHS III normative (2011/65/UE and following 2015/863).
Nome/Name: Giovanni Colasante
Posizione/Position: Amministratore Delegato/General Manager
Persona incaricata a costituire il fascicolo tecnico
presso la Sede/ Person authorized to compile the
technical file in Kolver
Thiene, 1° gennaio 2021 Giovanni Colasante

Other manuals for Kolver EDU1FR/SG

Questions and Answers

  • L
    Lisa SanchezAug 17, 2025
    What to do if Kolver Controller displays “Output Disabled”?
    • H
      hmoralesAug 17, 2025
      If the Kolver Controller displays “Output Disabled”, it means the protection of output signals was activated because the maximum load (400mA) was exceeded. Ensure the set load does not exceed the allowed maximum value. Restart the control unit to reset the error.
  • H
    hbridgesAug 20, 2025
    What to do if Kolver Controller displays “Transmission error”?
    • J
      Jennifer Castro MDAug 20, 2025
      If the Kolver Controller displays a “Transmission error”, it means the data transmission from the display board to the motor board is incorrect. Press ESC to retransmit data. If the error persists, restart the control unit.
  • P
    Paul GordonAug 23, 2025
    What does “Protection 12A” mean on Kolver Controller?
    • J
      Jodi ThomasAug 23, 2025
      If the Kolver Controller displays “Protection 12A”, it means the current on mosfets of bridge H is greater than 12A for at least 1 second. To resolve this: - Decrease cycle time and check settings. - Avoid motor stalling. - Avoid unscrewing too heavily. - Check if the joint is too soft.
  • B
    bandersonAug 26, 2025
    What does “Protection 14p5A” mean on Kolver Controller?
    • C
      Christina AndersonAug 26, 2025
      If the Kolver Controller displays “Protection 14p5A”, it means the current on mosfets of bridge H is greater than 14.5A for at least 800 ms. To resolve this: - Decrease cycle time and check settings. - Avoid motor stalling. - Avoid unscrewing too heavily. - Check if the joint is too soft.
  • B
    bakerwilliamAug 28, 2025
    What does “Protection 15A” mean on Kolver Controller?
    • A
      Andrew RossAug 28, 2025
      If the Kolver Controller displays “Protection 15A”, it means the current on mosfets of bridge H is greater than 15A for at least 500 ms. To resolve this: - Decrease cycle time and check settings. - Avoid motor stalling. - Avoid unscrewing too heavily. - Check if the joint is too soft.
  • K
    Krystal SmithAug 30, 2025
    What causes “Error loosen torque” on Kolver Controller?
    • J
      James ParkAug 31, 2025
      If the Kolver Controller displays “Error loosen torque”, it means the torque signal is displayed while loosening (only if it’s set on “max”). This can happen if: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • D
    David PeckSep 2, 2025
    What to do if Kolver Controller displays “Compensation error”?
    • A
      alison52Sep 2, 2025
      If the Kolver Controller displays “Compensation error”, a negative torque value is displayed due to a high negative compensation value. To fix this, increase or decrease the compensation value.
  • J
    Justin LeeSep 5, 2025
    What to do if Kolver Controller displays “tightened screw”?
    • N
      Nathaniel CollinsSep 5, 2025
      If the Kolver Controller displays “tightened screw” on the status bar (the torque signal is displayed during the motor startup process which lasted 0.3sec), check parameters once again.
  • V
    vmunozSep 8, 2025
    What does “Released lever error” mean on Kolver Controller?
    • S
      Sydney WilsonSep 8, 2025
      If the Kolver Controller displays “Released lever error”, it means the lever has been released while tightening. This error can be enabled or disabled through “PROGRAM-MENU”.
  • T
    Trevor JensenSep 12, 2025
    What to do if Kolver Controller displays “Error missing piece”?
    • D
      David Meza Jr.Sep 12, 2025
      If the Kolver Controller displays “Error missing piece”, it means the “missing piece” contact is enabled. Check contact 2 on the CN2 connector.

Summary

1. Applications

2. Use

3. Adjusting the torque

Details how to adjust the torque value by changing clutch spring tension and locking the nut.

4. Control unit and power supply

Explains the control unit's functions, power supply, speed/ramp adjustments, and indicators.

5. Maintenance

GUARANTEE

Kolver EDU1FR/SG Specifications

General IconGeneral
BrandKolver
ModelEDU1FR/SG
CategoryPower Tool