PC200/220(LC)-7 00-13
FOREWORD HOW TO READ ELECTRIC WIRE CODE
(14)
2. Dimensions
“f” of nominal No. denotes flexible”.
(Table 2)
Nominal No. 0.5f (0.5) 0.75f (0.85) 1.25f (1.25) 2f 2 3f 3 5
Conductor
Number of
strands/Diam-
eter of strand
20/0.18 7/0.32 30/0.18 11/0.32 50/0.18 16/0.32 37/0.26 26/0.32 58/0.26 41/0.32 65/0.32
Sectional
area (mm
2
)
0.51 0.56 0.76 0.88 1.27 1.29 1.96 2.09 3.08 3.30 5.23
d (approx.) 1.0 1.2 1.5 1.9 1.9 2.3 2.4 3.0
Cov-
er D
AVS Standard 2.0 2.2 2.5 2.9 2.9 3.5 3.6
AVStandard ––––4.6
AEX Standard 2.0 2.2 2.7 3.0 3.1 3.8 4.6
Nominal No. 8 15 20 30 40 50 60 85 100
Conductor
Number of
strands/Diam-
eter of strand
50/0.45 84/0.45 41/0.80 70/0.80 85/0.80 108/0.80 127/0.80 169/0.80 217/0.80
Sectional
area (mm
2
)
7.95 13.36 20.61 35.19 42.73 54.29 63.84 84.96 109.1
d (approx.) 3.7 4.8 6.0 8.0 8.6 9.8 10.4 12.0 13.6
Cov-
er D
AVSStandard–––––––––
AV Standard 5.5 7.0 8.2 10.8 11.4 13.0 13.6 16.0 17.6
AEX Standard 5.3 7.0 8.2 10.8 11.4 13.0 13.6 16.0 17.6