EasyManua.ls Logo

Kopp POWERversal - Delete Programmed Standby Power Value; Technical Data

Kopp POWERversal
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D
O
G
Delete the programmed stand-by power value:
Switch connected devices to stand-by mode.
Press the programming button „Prg.“ for
approximately 2 seconds.
Here, the green LED changes from constant
illumination to blinking and indicates that
the saved value has been deleted and a new
programming procedure is necessary for the
function.
The saved stand-by value is lost when the
power plug is pulled or there is a power
failure, indicated by the blinking, green LED.
This means it must be reprogrammed.
Technical data:
16A 250 V~ 50/60Hz
Recognizable stand-by power range: 5 W -
100 W
max. 3.600 W µ
Power consumption: approx. 0.5 W
IP 20
(LxWxH) approx. 482.6 x 71 x 58.3 mm
19“ width
Infrared sensor with sensor cable: approx.
1,5m
Green LED status display
Pushbuttons for the programming proce-
dure

Other manuals for Kopp POWERversal

Related product manuals