EasyManua.ls Logo

Korg Nu:Tekt NTS-2 - Tuner mode (TUNER); Explanations of each parameter

Korg Nu:Tekt NTS-2
4 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Tuner mode (TUNER)
Use the tuner to tune one of the four input signals. Both a horizontal meter and a nee-
dle-type (VU) meter view are available.
DISP: NEEDLE
DISP: METER
You can set the reference pitch to a value other than 440 Hz (this is also called “concert
pitch,” meaning a range from middle C to the A below that). With this function, you
can tune multiple oscillators at the same time by transmitting the same pitch (note) and
adjusting the pitch while monitoring.
Explanations of each parameter
Button#/NAME Pop Up Enc. Push Enc. Value
1: DISP
NEEDLE
--- ---
METER
2: INPUT
INPUT 1L --- ---
INPUT 1R --- ---
INPUT 2L --- ---
INPUT 2R --- ---
INPUT 1L
INPUT 1R
--- ---
INPUT 2L
INPUT 2R
--- ---
3: CALIB --- Set CALIB to 440 Hz A4 CALIB (410–480 Hz)
4: SCOPE SCOPE VIEW On, O --- ---
* e vertical range and horizontal range settings for scope view can be congured in
scope mode.
Global mode
Used for conguring the overall unit.
1: Input
Parameter Display Notes
Scope Trigger
INPUT 1L, INPUT 1R,
INPUT 2L, INPUT 2R
Congures what is triggered in
scope mode.
INPUT 1L
Coupling DC, AC
Sets the coupling for the input
signal. When this is set to AC
mode, the DC signal is cut.
Filter O, On
INPUT 1R
Coupling DC, AC
Filter O, On
INPUT 2L
Coupling DC, AC
Reduces high-frequency noise
included in the input signal.
Filter O, On
INPUT 2R
Coupling DC, AC
Filter O, On
2 : SETTINGS
Parameter Display Notes
Display
Brightness
0, 10, 20, ...80,
90, 100%
Sets the display brightness.
O time (USB)
1 min, 5 min,
10 min, 15 min,
innite
Sets how much time elapses before
the display is turned o when the
unit is connected to a USB power
source.
O time (Battery)
1 min, 5 min,
10 min, 15 min,
innite
Sets how much time elapses before
the display is turned o when the
unit is running on battery power.
Popup disp O, On
Sets popups (aside from the main
popups) to show or hide.
Scope slow mode Fixed, Scroll
Selects the display method for scope
mode, when “Sec/Div is set to a unit
of 100 ms or greater.
When this is “Fixed”, the screen is
cleared after the signal is displayed
up to the right edge of the screen,
and the signal begins displaying
again from the left side.
When this is “Scroll”, the signal is
scrolled to the left and displayed once
the display reaches the position set
in “Position”. (To show the signal over
the entire screen, move the “Position
all the way to the right edge.)
3 : SETTINGS
Parameter Display Notes
Power
Battery Type Alkaline, Ni-MH Selects the battery type.
Auto Power O
(USB)
5 min, 15 min,
30min, 1 hour,
ininiite
Sets the amount of time before
auto power-o is enabled,
when this unit is connected to
a USB power supply.
Auto Power O
(Battery)
5 min, 15 min,
30min, 1 hour,
ininiite
Sets the amount of time before
auto power-o is enabled,
when this unit is operating on
batteries.
Text i n boldface indicates the factory default setting.
Specications
Display: 2.8
RGB LCD
Input/Output jacks: INPUT 1, 2 jack (3.5 mm TRS mini phone jack), THRU 1, 2 jack
(3.5mm TRS mini phone jack), OUTPUT 1, 2 jack (3.5mm TS
mini phone jack), USB port (type C)
Power source: USB bus power (500 mA max.) or 2 AAA batteries (2 × alkaline
1.5V or 2 × NiMH 1.2 V)
Current consumption: 400 mA or less
Dimensions (W × D × H): 129 × 78 × 39 mm / 5.08
× 3.07
× 1.54
Weight: 130 g / 4.59 oz
Included items: USB cable, assembly instructions
Input/output jacks:
INPUT 1, 2 (stereo × 2)
Input impedance: 1 typ.
Maximum input voltage: −10 V to +10 V
THRU 1, 2 (stereo × 2)
OUTPUT 1, 2 (mono × 2)
Output impedance: 47Ω typ.
Maximum output voltage: −5 V to +5 V
Oscilloscope:
Display modes: Single, stereo (INPUT 1L-INPUT 1R, INPUT 1L-INPUT 2L,
INPUT 1R-INPUT 2R, INPUT 2L-INPUT 2R), 4 ch
Vertical 10 mV–10 V/div, switchable between AC/DC modes
Horizontal 50 us–1 s/div
Trigger: auto, rise, fall, single (rise), single (fall)
Function generator:
Waveforms: Oscillator, LFO, Noise, Pulse, Envelope
Frequencies: switchable between 0.01 Hz–10 kHz, Hz, NOTE and BPM modes
Output level: 10 Vpp max, switchable between V/dB modes
FFT:
Input: mono (1L, 1R, 2L, 2R)
Frequency range: 0 Hz–20 kHz
Tuner :
Display modes: needle meter (VU), horizontal meter
Inputs: mono, stereo (INPUT 1L-INPUT 1R, INPUT 2L-INPUT 2R)
Tuning: 12-note equal temperament
Detection range: E0 (20.60 Hz)–G8 (6,272 Hz), when inputting sine waves
Reference pitch range: A4 = 410–480 Hz (1 Hz steps)
Measurement accuracy: ±0.1 cents
* Specications and appearance are subject to change without notice for improvement.