[3] Writing of the Firewire GUID
The Firewire devices are needed to have a unique GUID for each device.
In the factory, there is a process to assign the GUID .
After changed the PCB by repairing, the new PCB's GUID is "0".
So you need to write the GUID before shipping.
[3.1:Equipments and tool]
1 WindowsXP computer (HomeEdition or ProfessionalEdition) with Firewire terminal
2 Firewire cable
3 BridgeCo 1394 DownLoad Tool (software): Same as the Firewire firmware update. Already installed?)
4 DM15Jig (software)
[3.2:Preparation ( install of the softwares)]
1 Install theBridgeCo 1394 DownLoadTool. When you already installed it, you need not.
2 Double click the DM15Jig(DM15JigSetup.msi) and install it.
[3.3:Process of the Firewire GUID writing ]
1 Start the DM15Jig (Fig12).
2 Click the"Preference" button and the setting screen is appears.(Fig13).
3 Check in the "Skip Slave Device Check", then click "OK".
4 Connect the WindowsPC and ZERO4/ZERO8 (Fig14).
5 After detected ZERO4/8, "Fig15" is displayed, then click the "Start" button.
6 Click the "OK" button (Fig16).
7 GUID writing screen is displayed. (Fig17)。
8 "Fig18" is displayed the writing has completed. Then turn the power off (ZERO4/8).
Fig9
Fig10
Fig11