Trouble - Shooting
If you have followed the instructions carefully and your faucet still does not work
properly, take the following corrective steps:
PROBLEM CAUSE ACTION
Leakage under the
handle
Adjusting locking nut
(4) has come loose
Remove handle index
button (1a). Loosen
set screw (1b) with
hex wrench (9).
Remove handle (2) (by
hand only). Tighten
locking nut (4) with an
adjustable wrench
Aerator drips or has
inconsistent water flow
pattern
Aerator (6) is dirty or
not seated properly
Unscrew aerator (6) with
aerator key (10) and
clean out debris
Water will not shut off
completely
Cartridge may be
defective
Remove handle index
button (1a). Loosen
set screw (1b) with hex
wrench (9). Remove
handle (2) (by hand
only). Unscrew trim
cap (3) (by hand only).
Unscrew the locking nut
(4) with an adjustable
wrench. Remove
ceramic disc cartridge
(5). Check for cracks
Leaking between spout
and body
Loose spout or
damaged O-rings on
connector
Tighten set screw under
the spout

Other manuals for Kraus FVS-1007

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kraus FVS-1007 and is the answer not in the manual?

Kraus FVS-1007 Specifications

General IconGeneral
BrandKraus
ModelFVS-1007
CategoryKitchen & Bath Fixtures
LanguageEnglish

Related product manuals