INSTRUCTION MANUAL
AIRMIX PUMP and LOW-PRESSURE PUMP
air motor with reversing block
Manual : 0306 573.002.212
Date : 12/06/03 – Supersedes : 17/06/02
Modif. § 1 + § 4 added
KREMLIN REXSON – Site de Stains : 150, avenue de Stalingrad
93 245 - STAINS CEDEX - FRANCE
Téléphone : 33 (0)1 49 40 25 25 Fax : 33 (0)1 48 26 07 16

Other manuals for Kremlin-Rexson airmix

Questions and Answers

  • C
    Courtney Shaw DDSAug 4, 2025
    Why is air always coming out of the Kremlin-Rexson Water Pump spray gun when priming?
    • J
      Jeffrey GeorgeAug 4, 2025
      If air is constantly coming out of the spray gun during priming, or if air (or material) fails to come out at all, it could be due to air intake at the fitting or suction rod. Ensure the spray gun is fully opened to allow air to evacuate. Inspect the pump valves. If a valve is stuck due to dried paint, try dislodging it by blowing air pressure directly through the suction fitting without disassembling the pump.
  • B
    bowmanadamAug 8, 2025
    What to do if the Kremlin-Rexson airmix does not start?
    • M
      Michael EllisAug 8, 2025
      If the pump fails to start, begin by checking the pump's air supply.
  • L
    Lisa HaleAug 13, 2025
    What to do if the Kremlin-Rexson Water Pump does not stop immediately when I shut off the spray gun?
    • O
      olsonjonathonAug 13, 2025
      If the pump continues to run after the spray gun is shut off, specifically if it stops only on the down stroke or only on the up stroke, examine the exhaust valve or valve seal, and the suction valve or upper cartridge.
  • B
    Benjamin JamesAug 19, 2025
    Why is the lubricant in the cup of my standard Kremlin-Rexson Water Pump quickly becoming discolored?
    • M
      Melissa RobbinsAug 19, 2025
      If the lubricant in the cup of your standard pump is rapidly becoming colored, inspect the upper packing. Try tightening the cup or replacing the seals if necessary.
  • C
    clementsamyAug 25, 2025
    What to do if my Kremlin-Rexson Water Pump doesn't reverse?
    • J
      jaime57Aug 25, 2025
      If the pump fails to reverse, check the spring of the air motor reversing block. Lubricate the reversing block with HP 150 oil. Also, verify the presence of pilot air, depending on the air motor model.
  • D
    Dalton CostaAug 28, 2025
    What to do if there is fluid leaking at the bottom of the air motor of my FLOWMAX ® Kremlin-Rexson Water Pump?
    • N
      nchambersAug 28, 2025
      If you notice fluid leaking from the bottom of the air motor on your FLOWMAX ® pump, check the bellow.

Summary

EC Declaration of Conformity

General Safety Instructions

Installation Requirements

Safety rules for installing equipment in a spray area, including ventilation and grounding.

Equipment Requirements

Precautions for high operating pressures, hoses, and pump grounding.

Hoses

Guidelines for selecting and maintaining hoses, ensuring they are static conductive.

Pump Safety

Requirements for grounding the pump and using compatible solvents.

Gun Safety

Safety measures for handling the spray gun, including depressurizing before servicing.

Maintenance Requirements

Rules for maintaining equipment, using only KREMLIN parts, and depressurizing before cleaning.

Operating Principle

Installation

Label Marking Description

Explanation of ATEX directive markings on the equipment label.

Installation Instructions

Diagram and explanation of installing the pump and spray gun in a spray booth.

Start Up Procedure

Filling

Detailed procedure for filling the pump with lubricant or solvent before startup.

Flushing with Solvent

Steps for flushing the pump and spray gun with solvent before use.

Priming with Material

Procedure for priming the pump with the actual material being sprayed.

Work Setup

Final steps for setting up the spray gun and adjusting pressure for work.

Circulating Pump Filling

Instructions for starting up a pump supplied in circulating mode.

Shutdown Procedures

Short Duration Shutdown

Steps for safely shutting down the equipment for a short period.

Long Duration Shutdown

Procedure for safely shutting down equipment for extended periods, including flushing.

Maintenance

Pump Maintenance

Routine maintenance tasks for the pump, including cleaning and strainer checks.

Spray Gun Maintenance

Maintenance guidelines for the spray gun, referring to its specific manual.

Filter Servicing

Instructions for servicing the fluid outlet filter, referring to its manual.

Safety Device

Troubleshooting Chart