POMPE A CHALEUR POUR PISCINE
SWIMMING POOL HEAT PUMP UNIT
UNIDAD DE BOMBA DE CALOR PARA PISCINAS
BOMBA DE AQUECIMENTO PARA PISCINAS
HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN
ZWEMBAD WARMTEPOMP
UNITÀ DI RISCALDAMENTO A POMPA DI CALORE PER PISCINE
VARMEPUMPE TIL SVØMMEBASSENG
LÄMPÖPUMPPU UIMA-ALTAALLE
VÄRMEPUMP FÖR BASSÄNG
ТЕПЛОВОЙ НАСОС ДЛЯ ПЛАВАТЕЛЬНОГО БАССЕЙНА
ISKBYKR RevB
Manuel d’instructions et d’installation
Installation & Instruction Manual
Manual de Instalación e Instrucciones
Manual de instalação e de instruções
Einbau- & Anleitungshandbuch
Installatie- en bedieningshandleiding
Manuale d’Uso e di Installazione
Installerings- og brukerveiledning
Asennus- ja ohjekirja
Bruksanvisning och installationsmanual
Руководство по монтажу и эксплуатации

Table of Contents

Questions and Answers

  • M
    Megan RobertsonAug 18, 2025
    What to do if my Kripsol Heat Pump shows high pressure protection?
    • D
      Derek LoweAug 18, 2025
      If your Kripsol Heat Pump displays a high pressure protection error, it indicates that the refrigerating circuit pressure is too high, the water flow is too low, the coil is obstructed, or the air flow is too weak. You should check the high pressure switch and the refrigerating circuit pressure. Also, verify the water or air flow, ensure the flow controller is working correctly, confirm that the water inlet/outlet valves are opening, and review the by-pass settings.
  • A
    Adam StokesAug 21, 2025
    Why does my Kripsol Komfort RC600 Heat Pump have low pressure protection?
    • E
      Emily BatesAug 21, 2025
      Low pressure protection in your Kripsol Heat Pump can occur if the refrigerating circuit pressure is too low, the air flow is too weak, or the coil is obstructed. Check the low pressure switch and the refrigerating circuit pressure for leaks. Clean the coil surface, check the fan rotation speed, and ensure free air circulation through the coil.
  • D
    Dr. James Smith Jr.Aug 23, 2025
    What to do if my Kripsol Komfort RC600 Heat Pump has a flow sensor fault?
    • H
      Heather DavisAug 23, 2025
      If your Kripsol Heat Pump indicates a flow sensor fault, it may be due to insufficient water flow, a short-circuited sensor, or a faulty sensor. Check the water flow, filtration pump, and flow sensor for any issues.
  • L
    Lori BaileyAug 26, 2025
    What to do if my Kripsol Komfort RC600 shows a water inlet sensor fault?
    • S
      stuartvargasAug 26, 2025
      If your Kripsol Heat Pump displays a water inlet sensor fault, it means the sensor is either open or has short-circuited. You should check or replace the sensor.
  • T
    Tammy HarrisAug 28, 2025
    What to do if my Kripsol Heat Pump shows a water outlet sensor fault?
    • D
      Denise MaynardAug 28, 2025
      If your Kripsol Heat Pump displays a water outlet sensor fault, it indicates that the sensor is either open or has short-circuited. You should check or replace the sensor.
  • M
    Matthew DoughertyAug 30, 2025
    What to do if my Kripsol Komfort RC600 displays an outside temperature sensor fault?
    • M
      Melissa PittsAug 31, 2025
      If your Kripsol Heat Pump shows an outside temperature sensor fault, this indicates that the sensor is either open or has short-circuited. Check or replace the sensor.
  • W
    Wendy MorrisonSep 2, 2025
    What does it mean if my Kripsol Komfort RC600 has a de-icing sensor fault?
    • P
      Patricia ThompsonSep 2, 2025
      A de-icing sensor fault on your Kripsol Heat Pump means the sensor is open or has short-circuited. Check or replace the sensor.
  • S
    Scott PerezSep 4, 2025
    Why is there a large temperature difference between outlet and inlet water in my Kripsol Komfort RC600 Heat Pump?
    • K
      katie38Sep 4, 2025
      A significant temperature difference between the outlet and inlet water in your Kripsol Heat Pump is caused by insufficient water flow volume or a water pressure difference that is too low or too high. Check the water flow and look for any system obstructions.
  • S
    Stephanie PattersonSep 7, 2025
    What to do if my Kripsol Komfort RC600 Heat Pump is in cold mode protection?
    • P
      Paul WhiteSep 7, 2025
      If your Kripsol Heat Pump is in cold mode protection, it is because the water output quantity is too low. Check the water flow rate or the temperature sensors.
  • J
    Jennifer OsbornSep 10, 2025
    How to fix communication problem in Kripsol Komfort RC600 Heat Pump?
    • X
      xturnerSep 10, 2025
      A communication problem in your Kripsol Heat Pump is due to a LED controller or PCB connection fault. Check the wiring.

Kripsol Komfort RC600 Specifications

General IconGeneral
ModelKomfort RC600
CategoryHeat Pump
Energy Efficiency Ratio (EER)3.2
RefrigerantR410A
Power Supply230V/1Ph/50Hz