7 Putasmallpieceofrag(about100mmx100mm)inthejawsofthesuppliedpickuptool,dipit
inthepan,lightit,anddropitbackintothepan.Youwillgetalittlebitofsmokefromthis,but
notforlong.
8 Placethecastironlidontop.
9 Switchtheon/offswitchtoON.[Pushthe
switch‘1’positiondown]
10 Afterabout10minutes,thestartingfuelwill
generateenoughheatforthethermostatto
switchontheoilpump,theblowerfanand
theindicatorlightonthecontrolbox.When
startingyourKOZYforthefirsttimeonly,
you’llgetsomesmokefromthenewpaint,
butitwon’tlastlong.Whentheheaterisup
andrunning,youcanpeekthroughthehole
inthelidandseethefingersofflame
burning,likegasjetsaroundtherimofthe
burnerbasin.
11 LeavetheKozyonLOfor20minutes.ThenyoucanswitchittoHIifdesired.Whenchanging
betweenHI&LO[highandlow]whileheaterisrunningholdtheleverstraightandfirmly,and
sortof“feel”yourwayup,acrossanddown,toensureproperengagement.(Ifyoudon’tyou
won’trealizethepumpisnotworkinguntilthefiregoesoutabout15minuteslater).
Ifusinglightoileg:diesel[warning]
Ifrunningonstraightheatingoilordiesel,useonlyontheLOsetting.Becausethisoilissothin
comparedtowasteoil,itwillflowthroughtheoilpumpatafasterrate.Thiscancauseyour
KOZYtorunmuchtoohotandshortenitslife.Ifyouwouldliketousedieselfuelorheatingoilin
yourKOZY,wehavetworecommendations.

Proptheblowerfanlidopenabout150mmwithanoncombustibleprop,(suchasapieceof
steel)toenablethefantodrawinsomecoolerair.
Thestopcockisnotusuallyusedasameteringdevice.Itisusuallyfullyopenorfullyclosed.
However,youcanrestricttheflowbyfindingapartialopeningpointwherethepumpis
deliveringabout2litresanhour.UseLOWonly.
Turningoff
Runonthe‘LO’settingfor20minutesbeforeturningoff.Toturntheheateroff,puttheswitchin
theOFFpositionandclosethemainstopcock.Afterabout15minutes,theflamewillgooutand
theheaterwillgraduallycooldown.Whenitdoes,thethermostatwhichswitchedtheblowerfan
on,willswitchitoff.