EasyManua.ls Logo

KSM-Stoker KSM-Multistoker 775-75 PCT 400 User Manual

KSM-Stoker KSM-Multistoker 775-75 PCT 400
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instructions
KSM-Multistoker 775-75
Producer:
KSM-Stoker
Make money by installing
1/ 10-2010 .
K
S
-Stoker
Næssundvej 440, 7960 Karby DK.
Tlf. +45 97761072
www.ksm-stoker.dk
Email. Mail@ksm-stoker.dk
M
A/S
With PCT 400

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the KSM-Stoker KSM-Multistoker 775-75 PCT 400 and is the answer not in the manual?

KSM-Stoker KSM-Multistoker 775-75 PCT 400 Specifications

General IconGeneral
BrandKSM-Stoker
ModelKSM-Multistoker 775-75 PCT 400
CategoryBoiler
LanguageEnglish

Summary

3.0 Control Panel

4.0 Menu Structure

4.5 Accessories

4.6 Boiler

4.7 Test

5.0 Starting Up the Stoker

6.0 Final Adjustments

7.0 Closing Down the Plant

8.0 Air Nozzles

9.0 Automatic Fuel Filling Device, Fire Damper / Transport Screw

10.0 Moving Floor (if mounted)

11.0 Ash Screw

12.0 Automatic Ignition (if mounted)

12.1 Ignition Problems

13.0 Boiler Cleaning

14.0 Hydraulic Feeding System (Hydraulic Moving Floor) (if mounted)

15.0 Precautionary Measures

15.1 Fire Protection, Thermal

Thermal protection mechanisms to prevent fires and manage overheating.

15.2 Personal Protection

Safety features like silo lid switch for personal protection during operation.

15.3 Electric Protection Fuses

Overload protection and fuses for motors and control components.

15.4 Maximum Heat Thermostat

Thermostat that interrupts control when the boiler exceeds 95°C, requiring manual reset.

16.0 Maintenance

16.1 Oxygen Sensor

Procedure for cleaning, checking, and calibrating the oxygen sensor for optimal combustion.

16.3 Fire Protection

Annual maintenance of the thermal valve and cleaning of the sawdust passage.

17.0 Service Plan

18.0 Breakdown

18.1 Unburned Fuel in the Ashes

Troubleshooting causes for unburned fuel in ashes, such as false air or incorrect settings.

18.2 The Boiler Becomes Sooty

Diagnosing and resolving issues leading to a sooty boiler, like false air or dirty sensors.

18.3 Black Display

Troubleshooting steps for a black or unresponsive control panel display.

18.5 The Screw Does Not Run

Troubleshooting scenarios where the stoker screw is not running or is stuck.

18.6 Backfire

Identifying causes and solutions for backfire incidents, including thermal valve triggers.

18.7 Clinker

Addressing clinker buildup in the screw tube area that can cause the screw to get stuck.

18.8 Bothering Smoke

Diagnosing bothering smoke originating from the tank or inspection door, indicating cleaning needs.

18.9 Condensed Water in Flue Gas Outlet

Understanding and preventing condensed water formation in flue gas ducts.

19.0 Alarm List