7SPECIFICATIONS
ENGLISH
GENERATOR
Model Unit
J320 J324
-STD -AUS -STD
Design
Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
Frequency Hz 50 60
Rated Output (COP)
kVA 20 20 10.8 23.5
kW 16 16 10.8 18.8
Rated Voltage V 380 415 240 220
Phase & Wire φ-w 3-4
Power Factor % 80 80 100 80
No. of Poles - 2
Insulation - Rotary coil: Class F, Stator coil: Class B
Voltage Regulation % 8 (No load to full load)
Type of Coupling Direct coupled
DIESEL ENGINE
Model V1305-BG-SEC
Design Vertical, water-cooled, 4-cycle diesel engine
No. of cylinders 4
Bore x stroke mm φ76 x73.6
Displacement L 1.335
Engine speed rpm 3000 3600
Lubricating Oil API service class CD or higher
Oil capacity L 5.7
Coolant capacity L 3.5
SET
Fuel Diesel fuel No. 2 (ASTM D975)
Fuel consumption (at full load) L 6.0 7.5
Fuel tank capacity L 79
Continuous Operating Hours hrs 13.0 10.5
Battery (V x Ah/5Hr) 80D26R(S) (12V x 55Ah)
Starting System Electric
L x W x H (with wheel) mm 1300 x 611 x 922
Approx Net Wt. kg 380
Output
Terminal - -
Receptacle - - -
Option Caster - -
Sound Level (full load at 7m) dB(A) 77.5 82.0
Emergency Stop System -
In case of abnormal:
Oil pressure, water temperature, fan belt broken
AMPS
AMPS A 30.4 27.8 15 x 3 61.7