INSTALLATION
OPERATION
vkids bl u, :e dyw j dks bLa VkyW djus ds dNq lkekU; fun'Zs k%
1) u, dUq LVkds keW Mts V+ Z dyw j dk s nhokj ;k gok jkds u s okyh fdlh
+
+
pht+ ls de ls de 10 ls eh njw bLa VkyW djAas dyw j dks fdlh
f[kMd+ h@njokts ds ikl yxk,a rkfd rkth gok vna j vk,A
2) boZ kikjs fs Vo dfw yxa d s fy, gok dk ?keq ko t:jh gAS blfy, fdlh
vU; f[kMd+ h@njokts dks t:j [kyq k j[ka s rkfd dejs dh xeZ
gok ckgj fudys vkjS gok dk cgs rj ?keq ko gkAs
3) dyw j ds eus dkMW Z dks nhokj ij yxs lkdW Vs ls yxk nAas ;g
n[s k ya s fd Iyx dh lgh vfFkx± gks vkjS og ^vkQW * gkAs
bLa VkyW djus dh uhps fy[kh dk;fZ of/k ls dyw j dks bLa VkyW djas%
1) ikuh Hkjuk% okYW o ea s ,d ¶yfs Dlcy ihohlh ikbi yxk dj
dyw j ds VdaS ea s 53 yhVj ikuh Hkj nAas ¼ikoj IokbVa ^vkQW *
dj ds ;g dke dj½as
okVj yos y bfa MdVs j VdaS Hkjus dk lda rs nxs kA ¶ykVs okYo
VdaS Hkjrs gh viu&s vki ykdW gks tk,xk ftlls ikuh vna j
vkuk #d tk,xkA
ikuh Hkjus dk nwljk rjhdk% dUq LVkds keW Mts V+ Z dyw j ds
lkeus okys fgLls ea s gh ^okVj buyVs Mkjs * g]S blfy, ikuh
Hkjuk vklku gAS vki okVj buyVs Mkjs dk s [kkys d s ex@ckYVh
ls VdaS ea s ikuh Hkj ldrs gAaS VdaS ds nlw js Nkjs ij vkos j¶yks
okYo gAS xyrh ls VdaS vf/kd Hkj tk, rks blh okYo ls ikuh
ckgj fudy tk,xkA ¼okYo ds uhps ,d ckYVh j[k n½as
2) fctyh vkiwfrZ% dwyj dk Iyx mlh oksYVst@fÝDosalh
vkmVyVs e as yxkuk pkfg, tk s crk;k x;k gAS ikoj IokbVa e as
lgh vfFkx± lfq uf'pr dj as vkjS fctyh dk fLop ^vkuW * dj nAas
3) daVªksy% LihM ukWc dks ¼1½ gkbZ] ¼2½ ehfM;e] ¼3½ yks
ysoy ij lsV djsa rkfd t:jr ds fglkc ls gok feysA
QaD'ku ukWc dk laca/k ofVZdy ywoj ds fLoax QaD'ku vkSj
lceflcZ y iEi l s gAS fLop ij nk s QDa 'ku vyx&vyx dke
ds fy, ga S tcfd rhljk ,d lkFk nkus ka s dk;k± s ds fy, gAS
baLVkWy djuk
dk;Zfof/k ¼vkWijs'ku½
Simple steps to install your new room cooler:
1) Place your new KUNSTOCOM DESERT COOLER atleast
10 cm away from the wall or any other obstruction
for air intake. The cooler should be placed near a
window/door to allow fresh air.
2) Circulation of air is important in evaporative cooling.
Always ensure that there is another window/door
open to exhaust warm air from the room and for
better circulation of air.
3) Plug in the main cord of your cooler to the wall socket,
ensuring that the plug is properly earthed & is in
OFF position.
Install the cooler as per following installation procedure:
1) FILLING OF WATER: Fill the water tank of cooler with
53 L of water through the valve using a flexible PVC
pipe (ensure the power point is OFF).
The water level indicator will show when the tank is full.
The float valve will ensure auto lock to cut-off the water
supply when tank is full.
Alternate way of filling: Your KUNSTOCOM DESERT
COOLER is provided with a 'Water Inlet Door' at the front
for easy filling. Just open the Water inlet door and pour
water into the tank using mug /tumbler. The overflow
valve at the other end of tank ensures water outlet
(put bucket beneath) when tank is overfilled accidently.
2) POWER SUPPLY: Ensure that your cooler is plugged into
specified voltage/frequency outlet only. Also ensure proper
earthing of power point. Switch ‘ON’ the power supply.
3) CONTROL: Rotate the SPEED knob to desired level viz.
(1) high, (2) med, (3) low to change air delivery.
The FUNCTION knob is associated with Swing function
of vertical louver & submersible pump. Two positions
on the Switch are for individual working while the third
position is for working both functions together.
Wind Supremo
Your Kunstocom cooler has been designed ergonomically
to provide you better comfort and performance. You can
enjoy the comfort it provides where you need it most.
Some of the applications where Kunstocom cooler can be
adapted are:
Living Room Bed Room Dining Room
Kitchen Balcony Study Room
Office Clinic Hotel Room
Restaurant Shop and many more
APPLICATION
• Always disconnect Main Power Supply before filling water.
• Do not fill water beyond the full mark on the water
level indicator.
• Do not move the cooler rapidly with tank full of water.
• Always disconnect Mains before opening panels.
• Be particular & careful when using the cooler near
curtains. Keep safe distance from curtains.
SAFETY PRECAUTIONS
CARE AND MAINTENANCE
dUq LVkds keW dyw j dh fMtk+ bu Je n{krk ds vu:q i gS tks vf/kd
vkjkengs vkjS 'kkunkj inz 'kuZ ds fy, t:jh gAS vki vius
vko';drk ds vulq kj blds vkjke dk vkuUn mBk ldrs gAS
dUq LVkds keW dyw j dbZ LFkkuka s ij mi;kxs h cuk, tk ldrs ga S tlS s%
• ges'kk esu ikoj lIykbZ dkV dj gh ikuh HkjsaA
• okVj yos ys bfa MdVs j ds mPpre fu'kku ls vkxs
ikuh u HkjAas
• ikuh Hkjk gks rks dyw j dks rts h ls b/kj&m/kj u [khpa Aas
• iuS y [kkys us ls igys ge's kk eUs l dkV nAas
• ink± s ds ikl dyw j mi;kxs djrs oDr ge's kk lrdZ jgAas
dyw j dks ink± s ls njw gVk dj j[kAas
mi;ksx
yhfoxa :e
fdpu
vkfW Ql
jLs =ka
cMs :e
ckYduh
fDyfud
'kkiW
Mkbfuxa :e
LVMh :e
gkVs y :e
vkfn
Lkqj{kk laca/kh lko/kkuh
Lkqj{kk
• dyw j mi;kxs ugha dj jgs gka s rks mlds lHkh fLop dks
^vkQW * j[kAas
• lHkh dVa kª ys dk mi;kxs vkjke ls djAas
• dyw j dks dkjs kfs lo dfS edYl] LØfcxa ikmMj ;k fFkuj ls u
ikNs a s & fQfuf'kxa [kjkc gkxs hA
• dyw j dks fgykus ;k nlw jh txg yxkus ls igys eus ikoj dkMW Z
dk Iyx fudky ya s vkjS okVj VdaS Hkh [kkyh dj nAas
• Mts V+ Z dyw j ds Åij Hkkjh lkeku u j[kAas
• VdaS ds ikuh ea s Cyhfpxa ,tVas u MkyAas
Lkqj{kk vkSj j[kj[kko
CARE
• When the cooler is not in operation, make sure that all
the switches are in the 'OFF' position.
• Operate all controls gently.
• Do not wipe the cooler with corrosive chemicals, scrubbing
powder or thinner, as they will damage the finish.
• Before moving or relocating the cooler, ensure that the Main
Power Cord is unplugged and the water tank is empty.
• Do not keep heavy load on the top of the desert cooler.
• Do not add any bleaching agents to the water of the tank.
Wind Supremo