CGP
STATUS TEST
TEST CGP
DMA? Press
YES
CHANNEL 1? Press
YES
or
NO
f
Each successive channel number will be asked until
aYE
S
response
is
given. Only one channel may be tested at a time.
During the
CGP status test, the test status will be displayed
on
the front panel LCD
as
follows:
EXAMPLE:
CSW:DOOF
AL 1:
E7F1
AL2:0000
In
the above example, the
CSW
is
the channel status word. The
four status digits are in hexadecimal.
If the test
is
progressing
correctly:
1.
The first CSW
digit
will usually vary from 0 to
F.
Occasionally, it will flash briefly from 0 to 5 or from F
to
7. If 5 or 7 are displayed for any appreciable length of
time, there may
be
a problem
on
the CGP board. Any number
or letter other than
0,
F,
5 or 7
in
the first character of the
CSW also indicates a problem
on
the
CGP
board.
2.
The second and third digits will increment
in
pairs from 00
to
FF.
3. The fourth CSW digit should always
be
F.
4. AL 1 will count
up
from 0000 to FFFF and then stop. When
AL
1 reaches FFFF, AL2 will start counting up from 0000
to
FFFF and then stop.
AL
1 will then begin counting up again
from
0000 to FFFF. AL 1 and AL2 will continue counting
up
alternately until
SELECT
is pressed.
NOTE:
If the following LCD display appears and does not
change, it usually indicates that
no
sample clock is present
at the channel sample DAC:
CSW: gOOF'
AL1: 0010
AL2: 0000
Kurzwell 250 Service Manual, Chapter 4