All Specifications are subject to change without prior notice.
TEMPERATURE CALIBRATOR
Preliminary Data
An ISO 9001:2008 Company
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659
Email : kusam_meco@vsnl.net, Website : www.kusamelectrical.com
An ISO 9001:2008 Company
®
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM-CAL-801.cdr
Model KM-CAL-801
ELECTRICAL SPECIFICATIONS - KM-CAL-801
í Basic Accuracy : ± 0.05%
í Display : 5 Digit LCD display.
í Max. Allowable Voltage : 30V..
í Operating Temperature Range : 0 ~ 50°C.
Humidity range : £ 80% RH
í Storage Temperature Range : £ -10°C ~ 55°C
Humidity range : £ 90% RH
GENERAL SPECIFICATIONS
This Calibrator is a source for Volts, Ohms RTD & Thermocouples. It gives output
of Volts in 2 ranges 100mV & 1000mV & also gives output of Ohms in 2 ranges
400W & 4000W & output for calibrating R, S, B, E, K, J, T & N type Thermocouples.
It also gives output for RTD Pt1000 & Cu50. It has very high accuracy 0.05%.
í Temperature Coefficient : 0.1 x (dedicated Accuracy) % /
°C (5°C ~ 18°C, 28°C ~ 40°C)
í Power Consumption : about 60m / 3V.
í Dimension : 180 (L) x 90 (W) x 47 (D) mm (with protector)
í Weight : About 500g
í Power : 1.5V x 2 alkaline batteries.
ACCESSORIES :
User Manual, Test lead CF-36, (Clips for probe),
Holster & Carrying case.
SAFETY :
Complies with IEC1010 (safety standard issued
by International Electrician Committee)
NEW
OUTPUT FUNCTION
100mV -10.00 ~ 110.00mV 0.01mV
±0.05% ± 30mV
The max. Output
current ± 2mA
DC Voltage
Output
Remarks
Accuracy
Output Range
Resolution
Range
1000mV -100.0 ~ 1100.0mV 0.1mV
±0.05% ± 0.3mV
400W 0.0 ~ 400.0W 0.1W
±0.05% ± 0.2W
OHM
4000W 0 ~ 4000W
1W
±0.05% ± 2W
±0.05 ~ ±0.3mA
Affiliated resistance of test lead is excluded.
The range of incentive current is from
0.05mA to 3mA & the maximum output
is less than or equals to 2V.
R
S
B
E
K
J
T
N
O
-40 ~ 1760 C
O
-20 ~ 1760 C
O
400 ~ 1800 C
O
-200.0 ~ 1000.0 C
O
-200.0 ~ 1370 C
O
-200.0 ~ 1200.0 C
O
-200.0 ~ 400.0 C
O
-200.0 ~ 1300.0 C
O
1 C
O
1 C
O
1 C
O
0.1 C
O
0.1 C
O
0.1 C
O
0.1 C
O
0.1 C
±0.05% + 3°C
O
(Less than or equals to 100 C)
O
±0.05% + 2°C (more than 100 C)
Employs ITS-90
temperature
standard
The accuracy does not
include the error of
interior temperature
compensation sensor
the range of interior
temperature compensation
sensor is from -10 to 50°C
& the error compensation
is less than or equals to
0.5°C
Thermo-
couple
RTD
O
±0.05% + 3°C (400 ~ 600 C)
O
±0.05% + 2°C (more than 600 C)
±0.05% + 2°C
O
(Less than or equals to -100 C)
±0.05% + 1°C
O
(more than -100 C)
Cu10
Cu15
Pt10
385
Pt100
385
Pt200
385
Pt500
385
Pt1000
385
O
-10.0°C ~ 250.0 C
O
-50.0°C ~ 150.0 C
O
-200.0°C ~ 850.0 C
O
-200.0°C ~ 850.0 C
O
-200°C ~ 630 C
O
-200.0 ~ 1200.0 C
O
-200.0°C ~ 630.0 C
O
0.1 C
O
0.1 C
O
0.1 C
O
0.1 C
±0.05% + 0.6°C
O
0.1 C
O
0.1 C
O
0.1 C
Incentive Current is
±0.5 ~ ± 3mA
When the incentive
current is ± 0.1 ~ 0.5mA,
add 0.5°C additional
error
Incentive Current is
±0.05 ~ ± 0.3mA
±0.5 ~ ±3mA
Affiliated resistance of test lead is excluded.
The range of incentive current is from
0.05mA to 3mA & the maximum output
is less than or equals to 2V.
Question and Answer IconNeed help?

Do you have a question about the Kusam-meco KM-CAL-801 and is the answer not in the manual?

Kusam-meco KM-CAL-801 Specifications

General IconGeneral
ModelKM-CAL-801
TypeMultifunction Calibrator
ThermocoupleJ, K, T, E, R, S, B, N
Input Impedance10MΩ
Operating Temperature0°C to 50°C
DC Current Range0-24mA
RTDPt100, Pt1000
DisplayLCD

Summary

General Specifications and Electrical Outputs

General Specifications

Covers basic accuracy, display, operating conditions, and physical dimensions of the calibrator.

Safety Compliance and Accessories

Mentions safety standards like IEC1010 and lists included accessories.

Safe Use and Meter Identification

Safe Use Guidelines

Crucial safety warnings, cautions, and notes for user protection during operation.

Meter Panel Components

Identifies and describes the physical controls and indicators on the meter's panel.

LCD Display Indicators

Explains the meaning of symbols and states shown on the LCD screen.

Instrument Operation and Maintenance

General Maintenance and Battery Replacement

Procedures for general maintenance, cleaning, and replacing batteries.

Power On/Off Operation

Instructions for operating the power functions of the calibrator.

Output Simulation Procedures

DC Voltage Output Simulation

Step-by-step guide to simulate DC voltage output.

Thermocouple (TC) Output Simulation

Steps for simulating thermocouple signals, including cold junction compensation.

RTD Output Simulation

Steps for simulating RTD signals with notes on resistance measurement.

Function Settings and Performance Index

Automatic Power Off Function Setting

How to configure the auto-off feature for the instrument.

Performance Specifications Details

Detailed accuracy, ranges, and notes for all output types.

General Product Features

Summarizes key product characteristics like power, measurement, and safety compliance.

Manual Notes and Documentation

Manual Notes and Disclaimers

Important user guidance and limitations regarding the manual's content.

Test Certificate Details

Details regarding the instrument's inspection and calibration.

Product Warranty Terms

Explains the terms and conditions of the product warranty.

Related product manuals