Do you have a question about the LABORIE Nexam Pro WPU-L4 and is the answer not in the manual?
Category | Medical Equipment |
---|---|
Model | Nexam Pro WPU-L4 |
Manufacturer | LABORIE |
Application | Urodynamic studies |
Display | Touchscreen |
Channels | 4 |
Device Type | Urodynamic System |
Connectivity | USB |
Software | Urodynamics Software |
Power Supply | Internal Battery |
Software Compatibility | Windows OS |
Description of the Nexam Pro measurement system and its modular setup.
Intended use of the Nexam Pro measurement system for urodynamic and anorectal testing.
Important safety information for users of the Nexam Pro measurement system.
Basic troubleshooting steps for system malfunctions and unexpected behavior.
Minimum computer requirements for running the LABORIE Windows software.
Steps to start and log in to the LABORIE database program.
Procedure for adding and selecting patient information in the database.
How to start the measurement program from the database program.
Steps involved in preparing the patient and system before an investigation.
Instructions for installing the Nexam Pump Unit (NPU) pump tube.
General procedures for preparing catheters and transducers for investigations.
Procedure for performing and verifying the quality check of the system.
Recommended cleaning and replacement procedures for system components.
General procedure for preparing various types of catheters and transducers.
Instructions for preparing reusable solid-state catheters for measurements.
Instructions for preparing single-use e•Sense solid-state catheters.
Instructions for preparing air-charged catheters and their connection.
Instructions for preparing and using water catheters with DT-XX transducers.
Definition and purpose of uroflowmetry as a diagnostic procedure.
Steps to perform a uroflowmetry investigation.
How to display and interpret uroflowmetry results and parameters.
Definition and purpose of cystometry for bladder function assessment.
Steps to perform a cystometry investigation, including remote control buttons.
Explanation of cystometry results and parameters, including bladder filling.
Description of the pressure-flow study, consisting of filling and voiding phases.
Steps to perform a pressure-flow study, including remote control buttons.
Interpretation of pressure-flow study results, including filling and voiding phases.
Definition and purpose of Urethral Pressure Profile (UPP) investigation.
Steps to perform a UPP investigation, including manual pull and puller use.
Analysis of UPP results, including Rest and Stress profiles.
Overview of the Gynecology study components: filling, UPP, and voiding phases.
Steps to perform a gynecology study, including UPP and manual pull.
Interpretation of gynecology study results, referencing other chapters.
Purpose and available tests for anorectal manometry investigation.
Settings and configurations for the anorectal manometry investigation protocol.
Procedure for selecting the appropriate catheter for anorectal manometry.
How to select and order the tests within the investigation protocol.
Detailed steps for performing various anorectal manometry tests.
Methods for analyzing anorectal manometry data using markers and settings.
Definition and application of biofeedback training for pelvic floor muscles.
Steps to prepare for a biofeedback investigation, including settings.
Procedure for conducting a biofeedback investigation with animations and challenges.
Configuring investigation protocols for biofeedback, including channels and challenges.
Overview of the Luna module for wireless measurements and ambulatory studies.
Procedure for performing a stationary measurement using the Luna module.
Steps to transition from a stationary to an ambulatory measurement with Luna.
Information on analyzing stationary and ambulatory measurements from the Luna module.
Overview of the measurement program's menu items and settings.
General information on investigation procedures within the measurement program.
Description of available tool buttons in the measurement program toolbar.
Information on using the RC-1600 remote control for investigations.
How to set up and edit investigation protocols for different studies.
Configuring display and layout settings for measurement channels.
Setting up channel numbers and connections for Nexam Pro measurement system.
Overview of the analysis program's features and functions.
Menu overview for accessing and displaying investigation results.
Steps to display and select parameters for investigation results.
Menu overview and functions for manipulating graphs in the analysis program.
Menu overview for inserting, managing, and describing markers.
Menu overview for various plot options and analysis tools.
General safety warnings and precautions for operating the Nexam Pro system.
Specific safety warnings related to the Nexam Pro trolley.
Safety warnings regarding the U2M module and its power supply.
Safety warnings and cautions for the Nexam Pump Unit.
Safety warnings for the combination interface module.
Safety precautions and warnings for the Luna wireless module.
Safety precautions and warnings for the Wireless Patient Module (WPM).
Safety precautions and warnings for the Wireless Patient Unit (WPU).
Safety warnings and cautions for the wireless Bluetooth flowmeter.
Safety warnings and precautions for the wireless Bluetooth puller.
Warnings and cautions regarding the use and handling of catheters and accessories.
Explanation of the blue symbol indicating reference to the instruction manual.
Explanation of the caution symbol advising to consult instructions.
Explanation of the yellow triangle symbol for general warnings.
Explanation of the symbol for Type BF applied part conformity.
Overview of software messages during measurement and analysis, with causes and resolutions.