Maximum Flow Ranges:
• T2C-075¾"Inlet/Outlet
0to25USgpm
(0to5.7m³/hr)
• T2C-1001"Inlet/Outlet
0to39USgpm
(0to8.9m³/hr)
• T2C-1501½"Inlet/Outlet
0to78USgpm
(0to17.7m³/hr)
Maximum Pressure:
• 100psiat73˚F
(6.9barat38˚C)
Temperature Range:
• 32˚F-120˚F
(0˚C-49˚C)
Mesh Sizes:
• 30Mesh(600Micron)
Element(Brown)
• 60Mesh(250Micron)
Element(White)
• 100Mesh(150Micron)
Element(Gray)
• 140Mesh(105Micron)
Element(Black)
Pre-Installation Checklist
A.Selectagoodlterlocation:
Installonthepressure(outlet)sideofanypumps
InaverticalpositionwithPurgeExitpointingdown
Awayfromextremeweatherconditionstoprotectfromfreezing
Atleast12inchesawayfromwalls,etc.sotophandlecanbetwisted
Allowenoughclearancebeneaththeunitto:
(a) attachapurgedrainhosetothePurgeExit(recommended)
(b) removetheclearbowlassembly,toallowreplacementofelementasneeded
B.Asasunnyoutdoorinstallationmightleadtoalgaegrowthinsidetheclearbowland
affecttheoperationofyourTWISTIICLEAN.AnoptionalSunShieldisavailable.
Safety Notes:
DespitetheeaseofinstallationandoperationoftheLAKOSTWISTIICLEANproduct,certain
precautionsshouldbetaken.
1. Lubricate“O”ringswithNSFapprovedsilicongreaseonly-Dow111isrecommended.
2. Donotovertightenthethreadedconnections.Donottightenmorethana1/4turnpastnger
tight.Handtightenthebowl,donotusetools.
3. Donotusewrenchesonplasticlterparts.Useoftoolsonlterwillvoidwarranty.
4. Forthreadedconnections,usetheTeon™tapesealantprovidedwithproduct.
5. Filtercomponentsthathave“O”ringsdonotrequirethreadsealant.
6. Removeclearbowlifthelteristobeinstalledusinganysolventwelding.Thiswillprevent
solventdamagetotheclearbowl.
7. Thislterisdesignedforusewithwateronly.Otherchemicalsorcomponentscandamagethe
ltercomponents.Evaluateallchemicalsforproperusagewiththelter.
8. Protectunitfromfreezing,asyouwouldwithanyotherwatersupplylines.
9. Followalllocalandstatecodes,laws,andregulationswheninstallinganylter.
TopHandle
RedSafetyLatch
Inlet
Outlet
FlowDirectionArrow
Mounting
Eyelets
ClearBowl
FilterElement
PurgeExit
IfforanyreasonthefilterelementdoesnotcleancompletelyduringthenormalTwisttoClean
operation,manualcleaningmaybeneeded.Inthiscase,removethebowlandcleantheelementwith
asoftbrush,brushingandrunningwateracrosselement.
Caution: If the lter bowl is to be removed, all water ow must be shut off going to the lter.
Limited Warranty
TheLAKOSTWISTIICLEANiswarrantedtobefreeofmaterialorworkmanshipdefectsforatleastoneyear
fromdeliverydate.
Ifafaultdevelops,notifyus,givingacompletedescriptionoftheallegedmalfunction.Includethemodel
number(s),dateofdeliveryandoperatingconditionsofsubjectproduct(s).Wewillsubsequentlyreviewthis
informationand,atouroption,supplyyouwitheitherservicingdataorshippinginstructionandreturnedmateri-
alsauthorization.Uponprepaidreceiptofsubjectproduct(s)attheinstructeddestination,wewilltheneither
repairorreplacesuchproduct(s),atouroption,andifdeterminedtobeawarranteddefect,wewillperform
anyproducts,damagesorinjuriesresultingfrommisuse,neglect,normalexpectedwear,chemically-caused
corrosion,improperinstallationoroperationcontrarytofactoryrecommendation.Nordoesitcoverequipment
thathasbeenmodifed,tamperedwithoralteredwithoutauthorization.Nootherextendedliabilitiesarestated
orimpliedandthiswarrantyinnoeventcoversincidentalorconsequentialdamages,injuriesorcostsresulting
fromanysuchdefectiveproduct(s).
LS-866(Rev.3/11)
Inlet/OutlettoPurgePort
TotalLength
TWISTIICLEAN
Installation Instructions for
3/4-inch Model T2C-075
1-inch Model T2C-100
1 1/2-inch Model T2C-150
Quick-Start Guide
Width
Dimensions
Total
Flow Rate (US gpm)
Flow Rate (m
3
/hr)
Clean Conditions
Head Loss (Bar)
Head Loss (psi)
=Recommendedowrange
2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0
0 10 20 30 40 50 60 70 80
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
www.TWISTIICLEAN.com
0
1
2
3
4
5
6
7
8
9
10
T2C-075 T2C-100 T2C-150
Max Flow=
25gpm 39gpm 78gpm