LAMBERT POWER Diesel Engine Operation and Maintenance Manual
Check radiator, clear or repair.
3. Water pump belt is loose.
4. Water pump gasket is damaged and water
pump impellers are worn.
Check and repair or replace.
5. Thermostat is in fault.
6. Water pipe is damaged and air leaks.
Check water pipe. Joints or washer. Replace
worn spares.
7.Oil level in soil sump is low or lack of oil.
Check oil level and oil leaks. Repair and add
oil.
6.10 Alternator doesn’t generate electricity.
1. Connected wires are cut off, short circuits, or
joints are loose.
Check wire connection in alternator and
ammeter.
2. Rotator, stator coil is cut, short circuit or
battery harness
3. Rectifier tube is damaged.
4. Insulation is broken, and conductor is cut.
5. Regulator adjusting voltage is low.
6. Regulator contact is burnt.