TAURA 24 MCS W TOP
CALDAIA MURALE A GAS CAMERA STAGNA, PER SANITARIO E RISCALDAMENTO
WALL-MOUNTING GAS BOILER AIRTIGHT CHAMBER, FOR HOT WATER AND HEATING
CHAUDIÈRE MURALE À GAZ CHAMBRE DE COMBUSTION ÉTANCHE, POUR LA PRODUCTION D’EAU CHAUDE SANITAIRE ET LE CHAUFFAGE
CALDERA MURAL DE GAS CON CÁMARA ESTANCA PARA AGUA SANITARIA Y CALEFACCIÓN
CALDEIRA MURAL A GÁS CÂMARA ESTANQUE, PARA PRODUÇÃO DE ÁGUA QUENTE SANITÁRIA E AQUECIMENTO
ΕΠΙΤΟΙΧΟΣ ΛΕΒΗΤΑΣ ΑΕΡΙΟΥ ΣΤΕΓΑΝΟΎ ΘΑΛΆΜΟΥ, ΓΙΑ ΖΕΣΤΌ ΝΕΡΌ ΚΑΙ ΘΈΡΜΑΝΣΗ
cod. 3540D95/0 ediz. 06/2006
AZIENDA CERTIFICATA ISO 9001
I
STRUZIONI PER
L’USO
L'INSTALLAZIONE
E LA MANUTENZIONE
INSTRUCTIONS
FOR USE,
INSTALLATION
AND MAINTENANCE
INSTRUCTIONS
D’UTILISATION,
D’INSTALLATION
ET D’ENTRETIEN
INSTRUCCIONES
PARA EL USO,
LA INSTALACIÓN Y EL
MANTENIMIENTO
INSTRUÇÕES DE
UTILIZAÇÃO
INSTALAÇÃO
E MANUTENÇÃO
ΟΔΗΓIΕΣ ΧΡΗΣΗΣ
ΕΓΚΑΤAΣΤΑΣΗΣ
ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ

Table of Contents

Questions and Answers

  • L
    Lauren BranchJul 30, 2025
    How to fix no burner ignition in LAMBORGHINI Boiler?
    • A
      Autumn KochJul 30, 2025
      If your LAMBORGHINI Boiler burner won't ignite, it could be due to several reasons. First, ensure that the gas flow to the boiler is regular. Then, check the wiring of the detection/ignition electrode to confirm it's correctly positioned and free of deposits. A defective gas valve could also be the culprit, so inspect and replace it if necessary. Finally, the ignition power might be too low, so try adjusting it.
  • J
    Jason SheppardAug 3, 2025
    What to do if the LAMBORGHINI Boiler shows low system pressure?
    • M
      Michelle ThomasAug 3, 2025
      If your LAMBORGHINI Boiler shows low system pressure, it might be because the system is empty or the water pressure switch is not connected or damaged. To resolve this, first, fill the system with water. If that doesn't work, check the water pressure sensor for any damage or connection issues.
  • J
    Jordan JonesAug 7, 2025
    Why does the safety thermostat trip on my LAMBORGHINI Boiler?
    • B
      Becky JohnsonAug 7, 2025
      If the safety thermostat trips in your LAMBORGHINI Boiler, it could be due to a damaged heating sensor, no water circulation, or air in the system. Check the heating sensor's position and operation. Inspect the circulator to ensure it's functioning correctly. Finally, vent the system to remove any trapped air.
  • H
    Hector EstradaAug 11, 2025
    What to do if the air pressure switch fails in my LAMBORGHINI Boiler?
    • S
      Sharon MitchellAug 11, 2025
      If the air pressure switch in your LAMBORGHINI Boiler fails to close within 60 seconds of the fan turning on, it could be due to several reasons. Start by checking the wiring to ensure it's correctly connected. Then, inspect the fan and the pressure switch itself. Also, the diaphragm might be faulty and require replacement.
  • S
    Sheri SmallAug 16, 2025
    Why is there a flame present with burner off signal in my LAMBORGHINI Boiler?
    • G
      gregory48Aug 16, 2025
      If your LAMBORGHINI Boiler shows a flame even when the burner is off, it might be due to an electrode fault or card trouble. Check the ionizing electrode wiring for any issues. If the wiring is fine, inspect the card.
  • J
    James SloanAug 20, 2025
    How to troubleshoot a delivery sensor fault in LAMBORGHINI Boiler?
    • A
      Adam AndersonAug 20, 2025
      If your LAMBORGHINI Boiler displays a delivery sensor fault, it could be due to a damaged sensor, shorted wiring, or broken wiring. You should check the wiring or replace the sensor.
  • R
    Randall HeathAug 25, 2025
    What causes a tap water sensor fault in LAMBORGHINI Boiler?
    • W
      wwatkinsAug 25, 2025
      If your LAMBORGHINI Boiler indicates a tap water sensor fault, it may be caused by a damaged sensor, shorted wiring, or broken wiring. Start by checking the wiring. If the wiring is intact, consider replacing the sensor.

Summary

1. OPERATING INSTRUCTIONS

1.1 Introduction to the Taura 24 MCS W TOP

Brief overview of the Taura 24 MCS W TOP boiler.

1.2 Control Panel Overview

Details of the boiler's control panel layout, selector, and LEDs.

1.3 Turning the Boiler On and Off

Step-by-step instructions for igniting and shutting down the boiler.

1.4 Water System Pressure Adjustment

Guidance on setting the correct water system pressure.

2. INSTALLATION GUIDELINES

2.1 General Installation Instructions

Essential guidelines for installation by qualified personnel.

2.2 Recommended Place of Installation

Requirements and suitability for the boiler's installation location.

2.3 Plumbing and Water Connections

Details on connecting water pipes and system requirements.

2.4 Gas Supply Connection

Instructions for safely connecting the gas supply to the boiler.

2.5 Electrical Connections

Guidelines for connecting the boiler to the electrical grid safely.

Room Thermostat and Timer Connections

Notes on connecting room thermostats and timer controls.

Electrical Terminal Board Access

Location of the electrical terminal block and its diagram.

2.6 Fume Ducts and Ventilation

Requirements for fume extraction and outlet ducts.

Diaphragm Installation and Pipe Connections

Diaphragm Selection for Coaxial Pipes

Guidance on choosing diaphragms for coaxial pipe configurations.

Diaphragm Selection for Separate Pipes

Guidance on choosing diaphragms for separate pipe configurations.

Coaxial Pipe Installation Details

Instructions for fitting coaxial fume and air pipes.

Separate Pipe Installation and Loss Calculation

Instructions for separate pipe connections and loss calculation.

3. SERVICE AND MAINTENANCE

3.1 Adjustments and Gas Conversion

Procedures for gas type conversion and burner pressure adjustment.

Test Mode Operation

How to activate and deactivate the boiler's test mode for diagnostics.

Burner Pressure Adjustment Procedures

Detailed steps for adjusting burner pressure settings.

Maximum Heating Output Adjustment

Guidance on adjusting the maximum heating output.

Ignition Power Adjustment

Instructions for adjusting the ignition power.

Installer Parameters Menu Overview

Explanation of the installer parameters and their modification.

Parameter 1: Max Heating Power Setting

Setting the maximum heating power parameter via LEDs.

Parameter 2: Gas Type Selection

Selecting the gas type (Natural Gas or LPG) via LEDs.

Parameter 3: Lighting Power Adjustment

Adjusting the lighting power parameter via LEDs.

Parameter 4: Heating Idle Time Setting

Setting the heating idle time parameter via LEDs.

Parameter 5: Pump Post-Circulation Time

Setting the heating pump post-circulation time via LEDs.

Parameter 6: Heating User Max. Setpoint

Setting the maximum heating temperature setpoint via LEDs.

Parameter 7: Hot Water User Max. Setpoint

Setting the maximum hot water temperature setpoint via LEDs.

Parameter 8: Hot Water Mode Configuration

Configuring the hot water mode setting via LEDs.

3.2 System Start-up Procedures

Pre-ignition Safety Checks

Essential checks before lighting the boiler for safety.

Checks During Boiler Operation

Verification steps during the boiler's normal operation.

3.3 Routine Maintenance

Seasonal Boiler and Flue Inspection Checklist

Annual inspection of boiler and flue for performance and safety.

Boiler Access and Combustion Analysis

Procedure for Opening the Boiler Casing

Steps for safely opening the boiler casing for internal access.

Combustion Analysis Measurement Procedure

Steps for performing and interpreting combustion analysis.

3.4 Troubleshooting Guide

Fault Diagnosis and LED Error Codes

How to interpret the self-diagnosis system and LED fault codes.

4. TECHNICAL SPECIFICATIONS

4.1 Dimensions and Connection Points

Technical drawings showing boiler dimensions and connection points.

4.2 General View and Main Components Identification

Diagram identifying key internal and external boiler components.

4.3 Detailed Technical Data Tables

Comprehensive tables for power, gas, heating, and electrical specifications.

4.4 Installation Diagrams

Pressure vs. Power Performance Diagrams

Graphical representation of pressure-power relationships.

System Head Capacity Diagram

Diagram illustrating the head available for the heating system.

4.5 Electrical Wiring Diagram

LAMBORGHINI Taura 24 MCS W TOP Specifications

General IconGeneral
TypeCondensing
Power Output24 kW
Gas SupplyNatural gas / LPG
MountingWall-mounted
Fuel TypeGas