- 0 -
User manual
Model:YL-2G06A
Read all the safety instructions carefully before use and keep this
instructions for further use.

Questions and Answers

Summary

Important Safe Guards

Components Diagram

Operating Introduction

Operation

Instructions for turning on the unit, setting humidity levels (40%-60%, CO), and automatic stop functionality.

Water Full

Describes the alarm signal, automatic compressor stop, and procedure after emptying the water container.

Water Drainage

Explains how to connect an optional drainage tube for permanent water removal, ensuring correct hose placement.

Defrosting

Maintenance & Cleaning

Troubleshooting

Specification

Overview

This document is a user manual for the LAMINOX dehumidifier, model YL-2G06A. It provides essential information for safe operation, usage, maintenance, and troubleshooting of the device.

Function Description

The LAMINOX YL-2G06A is a dehumidifier designed for indoor use. Its primary function is to reduce the humidity in a room, helping to prevent issues like mold growth and dampness. The device operates by drawing in humid air, removing moisture, and then releasing drier air back into the environment. It features an automatic defrosting function to ensure normal operation in low-temperature environments where frost might form on the evaporator surface.

Important Technical Specifications

  • Model: YL-2G06A
  • Power Supply: 230V/50Hz
  • Dehumidification Capacity: 10L/D (at 30°C and 80%RH)
  • Rated Power: 210W
  • Current: 0.95A
  • Refrigerant: R134a, 92g
  • Product Size: 290mm (width) x 190mm (depth) x 478mm (height)
  • Water Tank Capacity: 1.8L
  • Net Weight: 9.5Kg
  • Operating Temperature Range: Recommended ambient temperature is between 5°C and 35°C for optimum performance.

Usage Features

The dehumidifier is equipped with a control panel that includes several indicators and buttons for easy operation:

  • ON/OFF Button: To power the unit on or off.
  • HUMID Button: Allows the user to set the desired humidity level. Available settings are 40%, 50%, 60%, and "CO" (Continuous). "CO" mode indicates continuous dehumidification without a specific humidity setting. The machine will automatically stop when the detected humidity is less than or equal to 2% below the set value and restart when it's 2% above the set value.
  • TIMER Button: Used to set the working duration for 2 hours, 4 hours, or 6 hours. There is also an option for "No timer" for continuous operation.
  • WATER FULL Indicator: Illuminates when the water tank is full, triggering an alarm and automatically stopping the dehumidification process.
  • DEFROST Indicator: Indicates when the automatic defrosting function is active.
  • Water Tank: The unit collects condensed water in a removable 1.8L tank. When the tank is full, an alarm sounds, and the unit stops operating. The user must empty the tank and replace it correctly for the dehumidifier to resume operation after a three-minute compressor delay.
  • Continuous Drainage (Optional): The device supports permanent water drainage by connecting a drainage tube (not included) to the drain spout. It is crucial to ensure the end of the hose is lower than the drain opening to prevent water backup and flooding.
  • Portability: The unit features a handle for easier movement.

Maintenance Features

Proper maintenance ensures the longevity and efficient operation of the dehumidifier:

  • Cleaning the Casing: The casing is made of plastic and should not be placed in direct sunlight. For cleaning, only use a soft, clean cloth. Avoid using gasoline, paint thinner, or other harsh chemicals.
  • Water Tank Care: The water tank should be removed and handled with care. It needs to be emptied regularly when the "WATER FULL" indicator is on.
  • Filter Cleaning: The mesh filter can be removed by pulling it in the direction of the arrow. It can be cleaned using a vacuum cleaner or water. After cleaning, the filter should be placed in a ventilated area until it is completely dry before reinstallation.
  • Long-Term Storage: If the unit will not be used for an extended period, it should be switched off, unplugged, and the water reservoir emptied. After two days, it should be packed and stored in a dry and ventilated place.
  • Safety Precautions: Users are advised not to disassemble the unit or attempt repairs themselves. Any damaged supply cord must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid hazards.
  • Placement: Ensure there is at least 30 cm of clear space on all sides of the unit for proper ventilation. The inlet and outlet ventilation should never be blocked. The unit should be operated on a horizontal surface to prevent vibration and noise. It should not be placed near high-temperature appliances, windows, or in bathrooms.

LAMINOX YL-2G06A Specifications

General IconGeneral
BrandLAMINOX
ModelYL-2G06A
CategoryHumidifier
LanguageEnglish