User Manual
Thank you for purchasing our pocket scale. Please read all
operating instructions carefully before use. This electronic scale is
a precision instrument. With normal care and proper treatment, it
will provide years of reliable service.
Never load the scale with more than the maximal capacity. Over
loading can permanently damage it! Avoiding any exposure to
extreme heat or cold, your scale works better when operate at
normal room temperature. Always allow the scale to acclimate to
normal room temperature for at least 1 hour before use. Give your
scale sufficient warm up time, usually 30 seconds to give the
internal components a chance to stabilize before calibration. Keep
your scale in a clean environment.
Dust, dirt, moisture, vibration, air currents and a close distance to
other electronic equipment can all cause an adverse effect on the
reliability and accuracy of you scale.
Handle with care. Gently apply all items to be weighed onto tray
top. Although this scale is designed to be quite durable, try to
avoid rough treatment as this may permanently damage the
internal sensor.
Avoid shaking, dropping or otherwise shocking the scale. This is a
precision instrument and must be handled with extreme care.
Only operate the scale on a stable, vibration free surface.
Question and Answer IconNeed help?

Do you have a question about the LanteScale MH-500 and is the answer not in the manual?

LanteScale MH-500 Specifications

General IconGeneral
BrandLanteScale
ModelMH-500
CategoryScales
LanguageEnglish

Summary

General Usage Guidelines

Handling and Care Instructions

Follow instructions to prevent damage from overloading, dropping, and rough handling.

Optimal Operating Conditions

Ensure stable, vibration-free surface and normal room temperature for best accuracy.

Scale Warm-up and Acclimation

Allow scale to acclimate to room temperature for 1 hour and warm up for 30 seconds before use.

Scale Operation

Scale Components Overview

Diagram illustrating scale parts: LCD, ON/OFF, UNITS, LIGHT, TARE, PCS, Battery Compartment.

Basic Weighing Procedure

Place scale on flat surface, turn on, wait for 0.0, place object, use UNITS and LIGHT keys.

Tare Weighing

Tare Functionality

Place item on scale, press TARE, add net-weight-item when 0.0 is displayed.

Counting Function

Using the PCS Function

Weigh sample, hold PCS, press UNITS to set quantity, press PCS to confirm counting mode.

Switching Modes

Toggle between weighing and counting modes using UNITS or PCS keys.

Calibration

Calibration Procedure

Press ON/OFF, HOLD MODE for 3s, wait for CAL, add calibration weight, see PASS.

Specifications

Model and Capacity

MH-500, 500g capacity, 0.1g resolution, multiple units (g, oz, tl, ct, gn).

Operational Parameters

Auto calibration, tare full capacity, 30s auto-off, 50-86°F operation temp.

Physical Dimensions and Power

Scale: 120x62x20mm, Platform: 56x50mm, Power: 2x AAA batteries, Weight: 110g.

Package Contents

Included Items

Package includes one 500g/0.1g Electronic Digital scale and one User manual.