4: Configuration Using XML
EDS1100/2100 Command Reference 26
line
(Attribute of
“instance” is
a number.)
name
interface rs232, rs485 half-
duplex, rs485 full-
duplex
Default:
termination enable, disable Default: disable
state enable, disable Default: depends
on instance
protocol none, modbus rtu,
modbus ascii,
tunnel, ppp, lpd,
lpd or tunnel
Default:
baud rate Default: 9600 bits
per second
parity even, none, odd Default: none
data bits 7, 8 Default: 8
stop bits 1, 2 Default: 1
flow control none, hardware,
software
Default: none
xon char Accepts a control
character, for
example,
<control>
A represents
control-A Default:
<control>Q
xoff char Accepts a control
character, for
example,
<control>
A represents
control-A Default:
<control>S
gap timer <None>,
...
Default: <None>
threshold Default: 56 bytes
lpd
(Attribute of
“instance” is
a number.)
banner enable, disable Default: enable
binary enable, disable Default: disable
soj enable, disable Default: disable
eoj enable, disable Default: disable
formfeed enable, disable Default: disable
convert
newline
enable, disable Default: disable
soj text
eoj text
queue
name
Group
Name
Group Item Value Name Value Options Addition
Information