admin firmware bootcount
Syntax
admin firmware bootcount <0|1>
Description
Configures bootcount parameter that control how many times the SLC has failed to boot. If this
value reaches Boot Limit, the SLC will switch to the alternate boot bank. The SLC will switch to the
alternate boot bank only once. For example, if it fails to boot Boot Limit times on bank 1, it will
automatically switch to bank 2; if it fails to boot Boot Limit times on bank 2, it will enter advanced
recovery mode. If Boot Count has reached Boot Limit, setting this value to 0 will enable the SLC to
boot again. Default is 0, range is 0 - 1.
admin firmware bootlimit
Syntax
admin firmware bootlimit <3-20>
Description
Configures bootlimit parameters that control how many times the SLC will fail to boot before
switching to the alternate boot bank. After the SLC fails to boot 2 times Boot limit (so it has
attempted to boot Boot Limit times on each bank), the SLC will go into advanced recovery mode,
which may require support from Technical Support to resolve so that the SLC can be booted
again. Default is 3 boots, range is 3 - 20.
admin firmware bootdelay
Syntax
admin firmware bootdelay <3-1800>
Description
Configures bootcount parameters that control how seconds the bootloader pauses before booting
the SLC. The default is 3 seconds and the range is between 3 and 1800 seconds.
admin firmware highrestimers
Syntax
admin firmware highrestimers <enable|disable>
Description
Enables high resolution timers required for Performance Monitoring or disables high resolution
timers (the default). Changing this setting requires a reboot in order for the change to take effect.