Connects the UPS to the power outlet and explains the charging status indication.
Details how to plug in connected devices to the UPS for protection.
Instructions for turning the UPS on, off, or restarting it in different modes.
The LA-ON-DC UPS Adapter is a compact and reliable device designed to provide emergency power backup for various DC-powered equipment. It ensures continuous operation of essential devices during power outages, safeguarding against data loss and service interruptions.
The primary function of the LA-ON-DC UPS Adapter is to act as an uninterruptible power supply for DC-powered devices. It automatically switches to battery power when the main utility power fails, ensuring that connected equipment remains operational. This is particularly useful for devices such as routers, modems, set-top boxes, VOIP phone systems, surveillance systems, alarm systems, access control systems, and other critical telecom equipment. The adapter is designed to provide a seamless transition to battery power, preventing any disruption to the connected loads. It also features an automatic charging function, ensuring that the internal battery is always ready for use.
Installation of the LA-ON-DC UPS Adapter is straightforward. Users should first inspect the unit to ensure no damage occurred during shipping. To begin, plug the AC input plug (D) of the UPS into a wall outlet. The UPS will automatically turn on, and a green LED indicator will illuminate. If the internal battery is not fully charged, the UPS will automatically begin charging, and the green LED will flash to indicate the charging status. Once the UPS is powered and charging, connect the DC output connector (C) to the loads that require protection. This setup ensures that the connected devices are protected by the UPS unit, receiving continuous power even if the main utility power is interrupted.
The UPS is designed for automatic operation. When plugged into a wall outlet under normal utility conditions, it will automatically turn on. The Restart/Off Button (A) serves multiple purposes. If the UPS enters a fault mode, pressing this button allows for a restart of the unit. In situations where the UPS is operating on battery power and the user wishes to conserve battery life, pressing and holding the button for 5 seconds will shut down the UPS. Additionally, if utility power is unavailable and the battery is fully charged, this button can be used to manually turn on the UPS.
The device features a two-color LED indicator (B) that provides clear feedback on its operational status.
The LA-ON-DC UPS Adapter includes several features to aid in troubleshooting common issues.
To ensure safe and optimal operation of the LA-ON-DC UPS Adapter, several safety guidelines must be followed:
By adhering to these usage and maintenance guidelines, users can ensure the longevity and reliable performance of their LA-ON-DC UPS Adapter, providing consistent power protection for their critical DC-powered devices.
| Capacity | 1000VA / 600W |
|---|---|
| Input Voltage | 220/230/240 VAC |
| Output Voltage | 220/230/240 VAC |
| Frequency | 50/60Hz |
| Battery Type | Sealed Lead Acid (SLA) |
| Communication Interface | USB |