Infrared accuracy
(ambient temperature
= 25°C)
± 1,0°C + 0,1°C/degree (< 0°C)
± 1,0°C (0°C ... 15°C)
± 0,6°C (15°C … 35°C)
± 1,0°C (35°C ... 65°C)
± 1,5% (> 65°C)
Probe accuracy
(ambient temperature
= 25°C)
± 1,0°C (< -5°C)
± 0,5°C (-5°C … 65°C)
± 1,0% (> 65°C)
Emission coefcient 0.1 ... 1.0 adjustable
Display
LCD with multicolour
backlighting
Laser 2-point target laser
Laser wavelength 650 nm
Laser class 2 / < 1 mW
Power supply Batteries, 2 x 1.5 V, type AAA
Degree of protection IP 54
Operating conditions
-20°C ... 70°C, 80% rH,
no condensation,
Storage conditions
-20°C ... 70°C, 80% rH,
no condensation
Dimensions (W x H x D) 40 x 158 x 53 mm
Probe sensor L 95 mm / ø 3,3 mm
Weight (incl. batteries) 146 g
Technical revisions reserved. 07.17
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=thein
Information on maintenance and care
Clean all components with a damp cloth and do not use
cleaning agents, scouring agents and solvents. Remove
the battery(ies) before storing for longer periods. Store the
device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular
basis to ensure it produces accurate measurement results.
We recommend carrying out calibration once a year.