EasyManua.ls Logo

Latronics DC-1230 - Dip Switch Settings

Latronics DC-1230
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAFETY
* All Latronics Chargers have an isolation rating of 3500V between AC
and DC via the toroidal transformer, which ensures extremely safe and
risk free operation.
* All the switching electronics and control circuitry are on the DC output.
* The single pole circuit breaker assembly ensures that when the Charger
is switched OFF, it is isolated from the battery supply.
* The active and neutral of the 240V AC input are electrically isolated
from the battery negative, battery positive, and earth connections.
* The Charger AC input is connected directly to the transformer input
winding.
* Latronics Chargers have the AC input (active and neutral) floating with
respect to the DC and Earth. The Earth connection is connected to the
case only. This configuration provides the highest safety and most
flexibility for installation wiring.
* Recommended minimum generator size 1500VA.
* The AC fuse is located internally on the main PCB.
Fuse rating is Antisurge/Slow blow 5A.
Charger Isolation and Safety
Please refer to relevant Australian Standards for safety procedures.
8
The whole of the supplies have been subjected to the Quality
System Requirements in accordance with the conditions of AS/NZS
ISO 9002: 1994.
All items are manufactured with full traceability.
All DC Series 5 Stage Smart Chargers conform to the C-Tick mark
for the EMC emission standard EN55014.
STATEMENT OF QUALITY ASSURANCE
DIP SWITCH SETTINGS
In order to access these options you have to open the Charger. Before
altering the settings switch Charger OFF, adjust the setting and switch
Charger back ON again. We recommend these adjustments be carried
out by qualified personnel or your system installer.
ON ON Lead Calcium
ON OFF AGM
OFF ON Gel/SLA
OFF OFF Flooded (Factory Setting)
ON = Special Factory Test Function. Do not use for normal operation
OFF = Factory Settings
SW1 SW2 Battery Type
SW3 Temperature
SW4 Equalise
SW5 Silent Mode
SW6 Special
ON = COLD
OFF = HOT (Factory Settings)
ON = ENAB E (Factory Settings)
OFF = DISAB E
- Equalise Function is disabled when AGM/GEL battery type is
selected.
ON = ENAB E (Factory Settings)
OFF = DISAB E
L
L
L
L
*Note
AC WIRING
5
LOCATION OF DIP SWITCHES
Removable plug for access to selector switches.
Turn Charger OFF and disconnect AC power cord before removing plug.
: Replace plug before reconnecting Charger.Note