EasyManua.ls Logo

Lazer Safe PCSS-F Series - User Manual

Default Icon
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PCSS-F SERIES
Technical Manual
Additions
LS-CS-M-023
27 Action Road, Malaga WA 6090, Australia
PO Box 2368, Malaga WA 6944, Australia
+61 8 9249 4388 +61 8 9249 6011 info@lazersafe.com
Question and Answer IconNeed help?

Do you have a question about the Lazer Safe PCSS-F Series and is the answer not in the manual?

Summary

About This Manual

Document Objectives

Details the purpose and scope of the PCSS-F Additions Technical Manual.

Guide to Notes, Cautions and Warnings

Explains the meaning of symbols used for notes, cautions, and warnings in the manual.

Obtaining Technical Assistance

Provides contact information for technical support services.

FIO04 Input; Output Module

CN1 Connections

Details power supply connection for the I/O module via a 5-way terminal block.

CN3 Connections

Covers connections for emergency stop contactor and feedback via an 8-way terminal block.

CN5 Connections

Details connections for door and emergency stop switches via an 8-way terminal block.

CN7 Connections

Details valve monitor input connections via a 15-way terminal block.

I;O Module Specifications

Provides detailed technical specifications for standard, pulsed, and dual outputs/inputs.

CNC Press Controller Communications Interface

Serial Communications Interface Option

Details the serial communication parameters and error counts for the ser4_a9 option.

PCSS Safety Function Options

Down Enable Safety Function Options

Enables and controls the pressing beam movement based on solenoid valve control strategy.

Emergency Stop Function Options

Monitors system and press brake conditions to initiate an emergency stop.

Error Reset Function Options

Allows selection of error reset options for the PCSS software.

Valve Monitoring Function Options

Provides options for monitoring valve status and fault conditions.

Down Switch Function Options

Allows selection of down switch options for operator station control.

Auxiliary Connections

Special Mode Operation Selection

Details how to activate the physical input for special mode operation selection.

Kernel Operation

Movement Monitoring

Continuous check to ensure the press brake is not moving when the down switch is released.

Special Tools

Activates special tool features like flattening, hemming, or z-wing for operator safety.

Lazer Safe PCSS-F Series Specifications

General IconGeneral
SeriesPCSS-F
Operating Voltage24 V DC
ApplicationMachine Safety
TypeType 4
Protection HeightUp to 1800 mm
Resolution14 mm, 30 mm
Detection CapabilityFinger, Hand
Protection RatingIP65
ConnectionM12 Connector
StandardsIEC 62061, ISO 13849-1