LEAK TESTING
All internal gas connections of this appliance are double leak tested prior to packing and should not
need leak testing upon installation and use. It is important however to leak test the external
connections.
Before use, check all the gas connections for leak testing using the procedure listed below. If the
smell of gas is detected at any time, you should immediately stop using and get the entire system
tested for leaks by an approved technician.
BEFORE TESTING
Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent (hand dish washing soap) and one part water. You will
need a spray bottle or a brush to apply the solution to the fittings.
TO TEST
• Turn the burner valve OFF
• Apply the soap solution to all gas fittings. Soap bubbles would appear where a leak is present.
• If a leak is present, immediately turn the gas supply OFF and tighten leaky fittings.
• Turn the gas back ON and recheck.
• Should the gas continue to leak from any of the fittings, turn the gas supply OFF and contact
customer service where you bought the leaking part.