Do you have a question about the Leader LBO - 524 and is the answer not in the manual?
Model | LBO - 524 |
---|---|
Category | Test Equipment |
Type | Oscilloscope |
Bandwidth | 20 MHz |
Channels | 2 |
Vertical Sensitivity | 5 mV/div to 5 V/div |
Time Base | 0.2 µs/div to 0.5 s/div |
Max Input Voltage | 400 V (DC + AC peak) |
Display | CRT |
Input Impedance | 1 MΩ // 25 pF |
Power Supply | 100-240 VAC, 50/60 Hz |
Guidelines for selecting and applying the correct AC power voltage for safe and proper operation.
Specifies the maximum allowable input voltage for vertical and synchronization terminals to prevent damage.
Warns about operating in strong magnetic fields and potential waveform distortion.
Details operational limits for temperature and humidity to ensure instrument longevity.
Advises on managing CRT intensity to prevent screen damage and ensure clarity.
Provides safety precautions and methods for connecting to equipment without a transformer.
Details external features like hand carrier, legs, and power cord for user convenience.
Explains controls for the CRT display, including illumination, focus, and brightness.
Describes controls for the vertical amplifiers, including position, sensitivity, and polarity.
Details controls for setting up synchronization signals, including slope, level, and source.
Explains controls for managing sweep operations, including time base and delay time settings.
Describes the connectors and terminals located on the rear panel of the oscilloscope.
Guides on initial settings and power-up procedure to display a basic trace line.
Explains how to use the calibration waveform to check vertical gain and time axis.
Details specifications and operation of the X1/X10 probe for accurate measurements.
Provides guidance on proper probe connection, grounding, and notes for low-capacity probes.
Explains ALT and CHOP modes for displaying two waveforms simultaneously.
Covers methods and settings for achieving stable waveform synchronization for accurate display.
Describes methods for measuring AC voltage component using lead wires or X10 probes.
Details the procedure for measuring DC voltage using AUTO sweep and AC/GND/DC switch.
Explains how to measure the combined DC and AC voltage components of a signal.
Provides the formula and procedure for calculating time intervals using sweep speed and screen divisions.
Explains how to calculate frequency by measuring the period of a waveform.
Details methods for measuring pulse rise time using A sweep and B sweep.
Guides on measuring phase difference between two signals using dual trace.
Explains how to measure phase difference using Lissajous figures via X-Y mode.
Describes how to use the Z-axis input for intensity modulation of the CRT trace.
Illustrates the layout of main components and adjustment potentiometers on various PC boards.
Provides step-by-step instructions for adjusting key parameters like vertical gain, DC balance, and time axis.