ALL MODELS INPUT: 115 VAC, 50/60 Hz, 2.5 Amps
220 VAC, 50/60 Hz, 1.3 Amps
Outputs
SRT360 with RC-7 Cell Maximum output of hypochlorous acid equivalent to 0.54 kg of free available chlorine per
day @ 3.5 Amps per 24 hours @ Maximum setting (10)
SRT840 with RC-15 Cell Maximum output of hypochlorous acid equivalent to 0.54 kg of free available chlorine per
day @ 5.0 Amps per 24 hours @ Maximum setting (10)
Flow Rate Ideal: 25US Gallons/min./95 Liters/Min. (on external bypass)
Reverse Polarity Function (Standar
d in all models)
The Reverse Polarity Function is designed to automatically clean the cell blades, maximizing the cell’s ability to manufacture
chlorine or bromine.
This feature is only enabled when the GREEN CELL ON indicator is displayed. This feature is part of a start up cycle. Thirty
minutes after the Control Panel is energized, a polarity reversal occurs, which cleans the cell. There after, as long as the Control
Panel is allowed to operate continuously without a power interruption, an expected polarity reversal will take place approximately
every 3 hours of main filter pump operation. This setting is not selectable. Since the OUTPUT CONTROL DIAL effects the amount of
time the GREEN CELL ON indicator is displayed, it also has the same effect with regards to the Reverse Polarity Function.
NOTE: Before adding any make-up water to your pool, it is suggested that pretesting the make-up water for high pH, total
alkalinity and calcium hardness will aid in the adjustment of these levels before they become excessive.
If manual cleaning of the cell is required, please refer to page 5 for further details and instructions.