Time setting
A simple click on the PRG button will allow us to enter the
time modification mode, 3 steps: 1st click minutes, other click
hours and finally last click day of the week
Digital Thermostat
User manual
- Working ambient temperature 0 ~ 70 ° C / 32 ~ 156 ° F.
- Temperature display range 0-40 C / 32-104 F.
- Display accuracy 0.5 C or 1 F
- Insulation conditions in normal environment
- Contact capacity 5 A / 250 V (BW)
- Weekly program set by default
- NTC probe sensor (10k) 1%
- Temperature adjustment range 5-35 C / 41-95 F
- Dimensions (mm) 130 * 90 * 17
- Power supply two AA * 1.5V alkaline batteries
Product Specifications
To increase
Description Icons
Short press to switch between programmable mode and
manual mode
To decrease
By pressing briefly you set the clock, by long pressing
you access the programmable mode
Turn on / off
+
-
TOGETHER FOR 3 SECONDS
SET THE LOCK MODE
SET