INSTALLER / CONSUMER
SAFETY INFORMATION
Please read this manual
before installing and using
the heater.
WARNING:
If the infor
mation in
this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour’s phone. Follow the
gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Installer: Leave this manual
with the heater.
Consumer: Retain this
manual for futur
e r
efer
ence.
This is an unvented gas-fir
ed
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate
combustion and ventilation air
must be pr
ovided. Refer to the
Installation section on page 3.
Unvented
Gas-Fired Room Heater
Blue Flame Heaters
Models: RMC-LC10NG, RMC-LC10LP - 10,000 Btu/hr.
RMC-LC20NG(F), RMC-LC20LP(F) - 20,000 Btu/hr
RMC-LC30NG(F), RMC-LC30LP(F) - 30,000 Btu/hr
RMC-LC10NG(T), RMC-LC10LP(T) - 10,000 Btu/hr.
RMC-LC20NG(T),(F), RMC-LC20LP(T),(F) - 20,000 Btu/hr
RMC-LC30NG(T),(F), RMC-LC30LP(T),(F) - 30,000 Btu/hr
Infra-Red Heaters
Models:
RMC-LI10NG, RMC-LI10LP - 10,000 Btu/hr
RMC-LI18NG(F), RMC-LI18LP(F) - 18,000 Btu/hr
RMC-LI30NG(F),
RMC-LI30LP(F)
- 30,000 Btu/hr
RMC-LI06NG, RMC-LI06LP - 6,000 Btu/hr.
RMC-LI10NG
(T)
, RMC-LI10LP
(T)
- 10,000 Btu/hr
RMC-LI18NG
(T),(F)
, RMC-LI18LP
(T),(F)
- 18,000 Btu/hr
RMC-LI30NG
(T),(F)
, RMC-LI30LP
(T),(F)
- 30,000 Btu/hr
Users Operation and Installation Manual
(F)=Fan, (T)=Thermostat Gas Control
(F)=Fan, (T)=Thermostat Gas Control
07/05 Rev 3.

Questions and Answers

  • D
    Daniel CrawfordAug 15, 2025
    How to fix no spark at the pilot light on my Legacy (F) Heater?
    • A
      Andrew RomeroAug 16, 2025
      If there is no spark at the ODS pilot when you try to ignite your Legacy Heater, the ignitor electrode might be positioned wrong. Reposition the ignitor electrode. The ignitor electrode might be broken, so replace the electrode. Check if the ignitor cable is pinched or broken; free the cable, and if damaged, replace it. Also, verify the ignitor cable is connected to the ignitor electrode; if not, connect the cable to the electrode.
  • M
    montoyajoyAug 18, 2025
    What to do if my Legacy Heater smells like gas even when it's off?
    • D
      David DavisAug 18, 2025
      If you smell gas when the control knob of your Legacy Heater is in the OFF position, it could be due to gas leaks or a defective gas control. It is important to locate and correct any leaks immediately or consider replacing the gas control.
  • M
    Mr. Joshua Jones DDSAug 21, 2025
    Why does my Legacy (F) Heater smell like gas when it's burning?
    • K
      kmortonAug 22, 2025
      If your Legacy Heater smells like gas during combustion, the cause could be foreign matter in the gas or on the burner ports, the heater burning vapors from paint or impurities in the air, or gas leaks. Check the gas passageway and burner, ventilate the room and stop storing odor-causing products near the heater, and locate and correct any leaks immediately.
  • A
    andrewhunterAug 25, 2025
    Why does the pilot light go out when I release the knob on my Legacy (F)?
    • J
      juliewilsonAug 25, 2025
      If the ODS pilot light on your Legacy Heater lights but the flame goes out when you release the control knob, ensure you keep the control knob pressed in for about 30 seconds after the pilot lights. The safety interlock might be triggered, so wait one minute and try the ignition operation again. Other potential issues include a damaged thermocouple (replace it) or a loose thermocouple connection at the gas control valve (hand tighten until snug, then tighten 1/4 turn with a wrench).
  • K
    Krystal KaufmanAug 27, 2025
    What to do if my Legacy (F) Heater has a spark but won't ignite?
    • C
      Craig LynchAug 28, 2025
      If your Legacy Heater has a spark but no ignition, first ensure the gas supply is turned on and the control knob is in the pilot position and pressed in. If there is air in the gas lines, purge them and repeat the ignition operation.
  • C
    Christopher ParksAug 30, 2025
    Why won't the burner light on my Legacy (F) Heater after the pilot is lit?
    • E
      Edwin KennedyAug 30, 2025
      If the burner on your Legacy Heater doesn't light after the ODS pilot is lit, the burner orifice might be clogged. Try cleaning the burner orifice.
  • L
    Laura NortonSep 2, 2025
    Why does my Legacy Heater have a delayed ignition?
    • L
      Laura WilsonSep 2, 2025
      If your Legacy Heater has a delayed ignition, the main burner carry over ports might be clogged. Try cleaning the main burner ports.
  • J
    Jennifer WeaverSep 5, 2025
    Why isn't the burner plaque glowing on my Legacy (F)?
    • J
      Joshua WilliamsSep 6, 2025
      If the burner plaque(s) on your Legacy Heater does not glow, the plaque(s) may be damaged, so replace the burner. Also, make sure that the control knob is not set between locked positions; turn the control knob until it locks at the desired setting.
  • J
    James SandersSep 8, 2025
    Why are the flames yellow on my Legacy (F)?
    • N
      njohnsonSep 8, 2025
      If you notice yellow flames during burner operation on your Legacy Heater, there might not be enough air. Check the air passageways and burner for dirt and debris.
  • T
    Todd GeorgeSep 12, 2025
    Why is my new Legacy (F) Heater smoking and smelling?
    • H
      hjensenSep 12, 2025
      The slight smoke and odor during the initial operation of your Legacy Heater are likely due to residues from manufacturing processes and should stop after a few hours of operation.

Summary

Installer; Consumer Safety Information

Safety Warnings

Critical warnings regarding fire, explosion, and injury if manual is not followed.

Gas Leak Procedure

Step-by-step instructions on what to do if you smell gas.

Installation and Service Requirements

Guidelines for qualified personnel on installation and servicing.

General Information

Safety Precautions

Essential safety practices for the proper and safe use of the gas-fired room heater.

Safe Heater Operation

Guidance on proper operation, ventilation, and avoiding carbon monoxide.

Specifications

Model Specifications

Detailed technical data for various models including input rating, pressure, size, and weight.

Product Features

Safety Device

Explanation of the Oxygen Depletion Sensor (ODS) pilot safety system.

Ignition System

Details on the Piezo ignition system, requiring no external power.

Installation

Combustion and Ventilation Air

Requirements for adequate fresh air for combustion and ventilation.

Gas Type Verification

Ensuring correct gas type (Natural or LP) is used as indicated on the rating plate.

Required Installation Items

List of materials and tools needed before proceeding with heater installation.

Locating the Heater

Clearance Requirements

Minimum distances from furniture, walls, and ceiling for safe placement.

Preparing for Installation

Steps before installation, like unpacking, checking for damage, and selecting a location.

Mounting Methods

Wall Anchor Method

Instructions for securing the heater to walls using anchors and screws.

Floor Installation

Guidelines for installing the heater on a noncombustible flat surface.

Connect to Gas Supply

Gas Supply Piping System

Procedures for connecting the heater to the gas supply, including pressure testing.

Leak Testing Gas Connection

Steps for testing gas connections for leaks using a soap solution.

Operation Instructions

Manual Gas Control Operation

Step-by-step guide for lighting and operating the heater with manual gas control.

Thermostat Gas Control Operation

Step-by-step guide for lighting and operating the heater with thermostat gas control.

Lighting and Inspection

Manual Lighting Instructions

Detailed steps for lighting the pilot using matches or a lighter.

Pilot and Burning Inspection

Procedure for checking pilot and burner flame patterns after lighting.

Troubleshooting

Maintenance

Burner and ODS Pilot Cleaning

Instructions for cleaning the burner and ODS pilot assembly.

Cleaning Air Passageways

Procedure for cleaning air passageways and unit casings.

Accessories

Operation & Maintenance Instructions

Guidance for operating and maintaining blower accessories.

Blower Operation and Care

Blower Operation

Instructions for manually or thermostatically controlling the blower.

Blower Maintenance and Care

Guidelines for cleaning and maintaining the blower to prevent overheating.

Warranty

Service and Limited Warranty

Details of the product warranty, coverage, and claim procedures.

Legacy (F) Specifications

General IconGeneral
BrandLegacy
Model(F)
CategoryHeater
LanguageEnglish