Category | Test Equipment |
---|---|
Type | Occupancy Sensor |
Sensor Type | Passive Infrared (PIR) |
Mounting | Wall |
Coverage Area | 1000 sq ft |
Humidity Range | 0% to 90% RH (non-condensing) |
Input Voltage | 120/277/347 VAC |
Voltage | 120/277/347 VAC |
Time Delay | Adjustable from 30 seconds to 30 minutes |
Details on battery types, status display, and power saving features of the LMCT-100-2.
Explains how to navigate menus and adjust values using the LMCT-100-2 interface.
Description of the LMCT-100-2 main menu and its core functions.
View, adjust, save, and send sensor parameters like Time Delay, Sensitivity, and Trigger.
Utilize Test Mode for sensor walk tests and troubleshoot sensor coverage.
Save, recall, and send sensor configurations to efficiently program multiple devices.
Set up analog sensors connected via LMIO-201 using the DLM network.
Assign loads, bind them to buttons/sensors, and set load operation modes.
Configure load types (e.g., NonDim, Dimmed) and specific parameters for control.
Configure daylighting settings for specific or searched photosensors on the DLM network.
Select zone operating modes (Switched, Dimmed) and assign loads for daylighting control.
Configure LMLS-500 zone modes and assign loads to zones for daylighting.
Perform automatic or manual calibration for daylighting control to set light level targets.
Steps for calibrating LMLS-500 daylighting sensors.
Procedure for performing automatic daylighting calibration on LMLS-600 sensors.
Manual calibration and settings for Switched, Dimmed daylighting modes on LMLS-600.
Adjusting Day/Night setpoints, time delays for LMLS-400 daylighting.
Configure setpoints, time delays, and ramp rates for LMLS-500 zones.
Configure setpoints, time delays, and ramp rates for LMLS-600 zones.
Adjust override, hold off, scene, and after hours settings for LMLS-400.
Configure advanced daylighting parameters for LMLS-500 devices.
Manage daylight ratio, recommissioning, and diagnostic messages for LMLS-600.
Set photosensor control modes (Normal, Test, Demo, Disable) for DLM devices.
Configure Load, Scene, Rocker, and Group buttons with modes and fade times.
Link specific loads to buttons or rockers for desired control actions.
Adjust dimming parameters like trim and set trip points for switched loads.
Manually set the light level of a load without using a switch or button.
Configure BACnet network settings and view network status.
Access utilities for Smartwire, device identification, PnG reset, and room mode.
Define how loads respond to Load Shed commands via BACnet.
View status of loads, groups, light levels, and occupancy sensors.
View group status, parameters, and compare individual load vs. group settings.
Configure sensor response for relays during Normal and After Hours.
Configure panel location for astronomical schedules and set date/time.
Program schedules, holidays, and events for panel-based lighting control.
Define events, assign groups, and set times/days for automatic lighting control.
Designate specific dates as holidays for schedule adjustments.
Define groups by assigning loads and configuring sensor/dark/light event behavior.
Customize group behavior with parameters like Blink, Time Delay, and Sensor Behavior.
Utilize Smartwire for assigning loads to groups via room controller relays.
Program occupancy sensor events and actions for groups, including active days.
Configure dark/light events based on Astro or photo sensor triggers for groups.
Troubleshoot common problems with device communication and daylighting control.
Step-by-step guide to update the LMCT-100-2 firmware via micro-USB.
Information regarding Wattstopper product warranty terms and limitations.