18
Technical Data
Voltage V~
120 230 230 230 400
Power consumption W
2300 2300 3100 3680 5400
Frequency Hz
50/60
Max. air outlet
temperature
°C
650 650 800 650 650
Air volume (20 °C) l/min.
200 – 900
Max. static pressure Pa
820 1050
Emission level L
pA
(dB)
< 70
Weight kg
without power supply cord
2.2 2.2 2.3 2.2 2.4
Dimensions Page 3 (Size)
Mark of conformity
2
Approval mark
3
Protection class II
4
Technical data and specifications are subject to change without prior notice
Mains voltage cannot be switched over
PREMIUM SYSTEM
Heat output and air volume steplessly adjustable with potentiometer • •
Integrated power electronics • •
Protection against heating element or device overheating • •
Alarm output •
Integrated temperature control •
Remote control interface for temperature or power set point •
Remote control interface for air volume adjustment •
Integrated temperature probe •
Display for showing the setpoint and actual values (°C or °F) •