Electrical safety: DOUBLE INSULATED
Voltage V~
Power consumption W
Temperature °C
Air flow l/min.
Air pressure Pa
Noise emission level L
pA
(dB)
Weight kg
Size mm
100 120 200 230 50/60Hz
1400 1600 1400 1600
50 – 600, infinitely controlled
max. 230 (without nozzle)
ca. 3000 (30 mbar),
after ca. 24 h operating time
65
1.4 with 3m cord
ø 100 × 340, Handle ø 56
2
Line/mains
voltage can not
be switched over
APPROVAL MARKS
TECHNICAL DATA
Danger to life when opening the tool as live compo
nents
and connections are exposed. Unplug the tool before
opening it.
Incorrect use of hot-air blowers can cause fire and explosion
hazard, especially near combustible materials and explosive
gases.
The tool must be operated with supervision. Heat can
reach combustible materials, which are out of sight.
Store the tool indoors when not in use - out of the reach
of children.
For personal protection on building sites we strongly
recom-
mend the tool be connected to a GFCI (Ground Fault Circuit
Interrupter) or a RCCB (Residual Current Circuit Breaker).
The voltage rating stated on the tool must correspond to
the line/mains voltage.
Do not touch heater tube and nozzle when they are hot.
They may cause burns. Let the tool cool down. Do not
point hot-air flow in the direction of people or animals.
Protect tool from damp and wet.
FI
120
230
WARNING
CAUTION
This tool is CCA certified (CENELEC Certification Agreement).