Multiple Venting
The EL280UHE(X) furnace can vent in multiple positions. 
See FIGURE 18.
The make up box may be  removed  and  the  combustion 
air inducer may be rotated clockwise or counterclockwise 
90° to allow for vertical or horizontal vent discharge in a 
vertical  or  horizontal  cabinet  position.  Remove  the  four 
mounting
screws,  rotate  the  combustion  air  inducer  and  gasket 
(pressure switch should be above the combustion air in-
ducer in all positions), then reinstall the mounting screws. 
See unit Installation Instructions for more detail.
 IMPORTANT
The combustion air pressure switch must be moved 
for horizontal discharge air left position.
FLOW
AIR
vent pipe
In all positions route the wires away from moving parts and the heat of the inducer
motor to prevent damage to the wires. The pressure switch must be installed above
the CAI to prevent moisture from collecting in the hoses or switch.
FLOW
AIR
Vent Pipe
FLOW
AIR
Vent Pipe
Vent Pipe
Vent Pipe
vent pipe
FIGURE 18