Winterizing and Condensate Trap Care
1 -   Turn off power to the furnace.
2 -   Have a shallow pan ready to empty condensate 
water.
3 -   Remove the clean out cap from the condensate trap 
and empty water. Inspect the trap then reinstall the 
clean out cap.
Cleaning The Burner Assembly
If cleaning the burner assembly becomes necessary, fol-
low the steps below:
1 -   Turn off electrical and gas power supplies to furnace. 
Remove upper and lower furnace access panels.
2 -  Disconnect the wires from the gas valve.
3 -  Remove the burner box cover (if equipped).
4 -   Disconnect the gas supply line from the gas valve. 
Remove gas valve/manifold assembly.
5 -   Mark and disconnect sensor wire from the sensor. 
Disconnect wires from ame rollout switches.
6 -   Disconnect combustion air intake pipe. It may be 
necessary to cut the existing pipe to remove burner 
box assembly.
7 -   Remove four screws which secure burner box 
assembly to vest panel. Remove burner box from 
the unit.
8 -   Use the soft brush attachment on a vacuum cleaner 
to gently clean the face of the burners. Visually 
inspect the inside of the burners and crossovers for 
any blockage caused by foreign matter. Remove 
any blockage.
9 -   Reinstall the burner box assembly using the existing 
four screws. Make sure that the burners line up in 
the center of the burner ports.
10 -  Reconnect the sensor wire and reconnect the 2-pin 
plug to the ignitor wiring harness. Reconnect wires 
to ame rollout switches.
11 -  Reinstall the gas valve manifold assembly. 
Reconnect the gas supply line to the gas valve. 
Reinstall the burner box cover.
12 - Reconnect wires to gas valve.
13 - Replace the blower compartment access panel.
14 -  Refer to instruction on verifying gas and electrical 
connections when re-establishing supplies.
15 -  Follow lighting instructions to light and operate 
furnace for 5 minutes to ensure that heat exchanger 
is clean and dry and that furnace is operating 
properly.