Page 27
TABLE 17
Maximum Allowable Intake or Exhaust Vent Length in Feet
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must
be same pipe size
.
Standard Termination at Elevation 0 - 4500 ft
Number
Of 90°
Elbows
Used
1-1/2” Pipe 2” Pipe 2-1/2” Pipe 3” Pipe
Model Model Model Model
045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135
1 25 20
n/a n/a n/a
81 66 44 24
n/a
115 115 93 58
n/a
138 137 118 118 114
2 20 15 76 61 39 19 110 110 88 53 133 132 113 113 109
3 15 10 71 56 34 14 105 105 83 48 128 127 108 108 104
4 10
n/a
66 51 29
n/a
100 100 78 43 123 122 103 103 99
5
n/a
61 46 24 95 95 73 38 118 117 98 98 94
6 56 41 19 90 90 68 33 113 112 93 93 89
7 51 36 14 85 85 63 28 108 107 88 88 84
8 46 31
n/a
80 80 58 23 103 102 83 83 79
9 41 26 75 75 53 18 98 97 78 78 74
10 36 21 70 70 48 13 93 92 73 73 69
Standard Termination Elevation 4500 - 10,000 ft
Number
Of 90°
Elbows
Usedl
1-1/2” Pipe 2” Pipe 2-1/2” Pipe 3” Pipe
Model Model Model Model
045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135
1 25 20
n/a n/a n/a
81 66 44
n/a n/a
115 115 93 58
n/a
138 137 118 118 114
2 20 15 76 61 39 110 110 88 53 133 132 113 113 109
3 15 10 71 56 34 105 105 83 48 128 127 108 108 104
4 10
n/a
66 51 29 100 100 78 43 123 122 103 103 99
5
n/a
61 46 24 95 96 73 38 118 117 98 98 94
6 56 41 19 90 90 68 33 113 112 93 93 89
7 51 36 14 85 85 63 28 108 107 88 88 84
8 46 31
n/a
80 80 58 23 103 102 83 83 79
9 41 26 75 75 53 18 98 97 78 78 74
10 36 21 70 70 48 13 93 92 73 73 69
See concentric terminations next page.