Page 42
Optional Accessories for use with any icomfort Touch
®
 System
FIGURE 58
NOTE: 24V UV LIGHT
APPLICATIONS
In an icomfort by Lennox system,
neither furnace nor air handler
transformer will have adequate VA
to power 24V UV light applications.
An additional transformer for UV
light applications is required.
Icomfort Wi-Fi
®
THERMOSTAT
Discharge Air Sen
sor (Required for
even heat)
NOTE: Icomfort Wi-Fi
®
 THERMOSTAT SENSES HUMIDITY &
CONTROLS HUM CONTACTS TO CYCLE HUMIDIFIER BASED
ON DEMAND. NO OTHER CONTROL OR HUMIDISTAT RE
QUIRED.
OPTIONAL OUTDOOR AIR SENSOR FOR USE WITH HUMIDI
FIER (IF NOT ALREADY IN THE SYSTEM FOR OTHER FUNC
TIONS. BUILT INTO ALL icomfort by Lennox OUTDOOR UNITS).
Maximum total
length of all connec
tions on the RSBus
is limited to 1500ft.
Wire gauge of
RSBus wire is 18.
RSBus
Rf WGhGsCf
HVAC EQUIP
DEHUMIDIFIER
CONTROL
HVAC
EQUIPMENT
DH
STANDARD 1 OR 2 STAGE
AC OR HP UNIT
*24V IN
JUMPER
icomfort
®
  ENABLED
EL296UHV FURNACE
icomfort  ENABLED
EL296UHV FURNACE
Icomfort Wi-Fi
®
THERMOSTAT
CONVENTIONAL NON-
COMMUNICATING
SYSTEM
COMMUNICATING
SYSTEM
CS 7000
THERMOSTAT
*24V IN jumper not used in non-
communicating configuration
24V HUMIDIFIER CONNECTIONS
120V CONNECTIONS
HEPA BYPASS FILTER X2680 HEPA INTERLOCK KIT
PASS INDOOR BLOWER MO
TOR COMMON WIRE
THROUGH CURRENT LOOP.
SEE HEPA INTERLOCK KIT
FOR INSTALLATION DETAILS
LVCS VENTILATION CONTROL SYSTEM
SEE LVCS VENTILATION
INSTRUCTIONS FOR DAMPER &
SENSOR WIRING
icomfort
®
  ENABLED
EL296UHV FURNACE
 
icomfort
®
ENABLED OUTDOOR AIR
CONDITIONING OR HEAT
PUMP UNIT
(POWER COMPANY INTERRUPTION SYSTEMS ARE
WIRED SAME AS OVERFLOW SWITCH)
icomfort
®
  ENABLED
EL296UHV FURNACE
CUT R-DS
W914
DS
R
2 STAGE FURNACE
COMMUNICATING
SYSTEM WIRING
NON-COMMUNICATING
SYSTEM WIRING
“HUM” CONTACT IS
CLOSED ANYTIME
HUMIDITY DEMAND
IS PRESENT
icomfort
®
  ENABLED
EL296UHV FURNACE