BLOWER DATA
EL296UH090XV36C BLOWER PERFORMANCE (less lter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1215 1300
+18% 1140 1240
+12% 1100 1170
+6% 1020 1115
Factory Default 965 1070
–6% 915 970
–12% 850 925
–18% 805 855
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 625 710 830 950 875 1040 1210 1360
Factory Default 565 670 760 860 800 945 1100 1245
520 610 685 785 720 840 970 1115
BLOWER DATA
EL296UH090XV48C BLOWER PERFORMANCE (less lter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1490 1645
+18% 1415 1565
+12% 1330 1480
+6% 1295 1405
Factory Default 1220 1325
–6% 1150 1260
–12% 1065 1190
–18% 1010 1105
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 840 1005 1155 1315 1165 1375 1580 1770
Factory Default 780 915 1045 1190 1075 1265 1440 1645
690 835 955 1070 935 1145 1320 1465
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 380 cfm.
Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 380 cfm.