• 22 •
FAC FAH
FAG FAM
FLEXAIR 085 100 120
15000 18500 20500
86,0 101,3 119,3
20,1 27,1 31,4
FAC 2,71 4,08 5,28
FAG 3,26 5,14 6,65
67,5 75,5 103,2
209,3 252,3 293,9
FAC 3,56 3,30 3,29
FAC 3,24 2,92 2,85
FAG 3,15 2,80 2,73
85,0 100,0 117,5
20,6 27,1 31,3
FAH 2,71 4,08 5,28
FAM 3,26 5,14 6,65
FAH 3,52 3,26 3,24
FAH 3,20 2,88 2,81
FAM 3,11 2,76 2,69
FAH 78,4 94,7 109,0
18,3 22,9 28,6
FAH 2,71 4,08 5,28
FAM 3,26 5,14 6,65
FAH 3,60 3,58 3,26
FAH 3,39 3,32 3,01
FAM 3,34 3,24 2,94
S
(4)
55,2
H
(4)
110,4
S
(4)
60
H
(4)
120
92
S
(4)
6,3
H
(4)
12,5
2
FAC-FAG
9 / 9 9,1 / 9,1 9,1 / 9,1
FAH-FAM
9,1 / 9,1 9,2 / 9,2 9,2 / 9,2
15000 18500 20500
12000 14000 15000
23000 23000 23000
150 / 800 150 / 800 150 / 800
Application Guide / FLEXAIR-AGU-1505-E
3- GENERAL DATA
Cooling only Heat pump
Cooling only with gas red heating Heat pump rooftop with gas red heating
(1) All data are at Eurovent conditions (400V/3Ph/50Hz at nominal air ow rate),
nominal external static pressure.
Cooling :
Outdoor temperature = 35°C DB
Entering coil temperature 27°C DB / 19°C WB
Heating :
Outdoor temperature = 7°C DB / 6°C WB
Indoor temperature = 20°C DB
(2) Including compressor + outdoor axial fan + indoor centrifugal fan
(3) Net COP = Net cooling capacity/Total absorbed power
(4) S = Standard heat / H = High heat
(5) At nominal air ow rate
Casing F BOX
Nominal air ow rate m
3
/h
Cooling mode (FAC - FAG)
Gross cooling capacity
(1)
kW
Compressor gross power input
Indoor fan absorbed power
Full load amps
(1)
A
Direct start up amps ratio Id/Ia
Gross EER
(2)
Global net EER
(3)
Cooling mode (FAH - FAM)
Gross cooling capacity
(1)
kW
Compressor gross power input
Indoor fan absorbed power
Gross EER
(2)
Global net EER
(3)
Heating mode (FAH - FAM)
Net heating capacity
kW
Compressor gross power input
Indoor fan absorbed power
Gross COP
(2)
Global net COP
(3)
Heating - Gas red
Heating capacity kW
Power input kW
Thermal ef ciency %
Gas ow (for natural gas at 20 mbar and 15 °C) m
3
/h
Refrigeration circuit
Number of circuits
1 scroll + 1 scroll
Compressor type and number
Expansion valve number
Refrigerant charge per circuit 1/2 kg
Ventilation data
Nominal air ow rate
m
3
/hMinimum air ow rate
Maximum air ow rate
External static pressure / Maximum
(5)
Pa

Related product manuals