Page 32
FIGURE 49
To Remove Blower:
1- Turn off line voltage power. Unplug
J69  from  P69  located  on  blower
deck.
2- Disconnect thermostat wiring conĆ
nections by removing low voltage
terminal strip.
3- Disconnect J58/P58 located on blowĆ
er deck.
4- Disconnect  J43/P43  from  blower
motor.
5- Loosen screws (2) and remove conĆ
trol box from unit. Holes are slotted so
screws do not need to be removed.
6- Remove  screws  (2)  and  remove
blower from unit.
4
5
26
3
1
5
FIGURE 50
BLOWER SPEED TAP SELECTION
HARNESS
CONNECTOR
MOTOR
DEPRESS  TAB  TO  RELEASE
WIRE  TERMINAL.  SELECT
CONNECTOR LOCATION FOR
NEW SPEED (REFER TO UNIT
WIRING  DIAGRAM).    INSERT
WIRE UNTIL IT IS SECURELY
IN PLACE.
TABLE 12
TABLE 13
E-Blower Speed Taps Leaded Motors
-5 and -6 Models
Blower speed  tap  changes  are  made  on  the  SureLight
control board. See figure 10.  Unused taps must be  seĆ
cured on dummy terminals "PARK M1" and or "PARK M2"
on the SureLight board. The heating tap is connected to
the "ACB HEAT " terminal and the cooling tap is connected
to the "ACB COOL" terminal. The continuous blower tap is
connected to the "ACB LOW" terminal.
To change existing heat tap, turn off power then switch out
speed tap on "ACB HEAT" with tap connected to "PARK
M1" or "PARK M2". See table 13 for blower motor tap colĆ
ors for each speed.
VI-MAINTENANCE
Retainers for factory supplied return air filter are shown in
figure 51.
FIGURE 51
BOTTOM RETURN FILTER
FURNACE
BASE BOTTOM
REAR FILTER CLIP
RETURN AIR
OPENING
SIDE FILTER CLIPS (2)
FURNACE
FRONT
FURNACE
BACK
A-Filters
At  the  beginning  of  each  heating  season,  the  system
should be checked as follows:
1 - Filters  should  be  inspected  monthly  and  must  be
cleaned or replaced when dirty to ensure proper furĆ
nace operation.