TABLE 4
KG/KC 092S CAV and Staged Blower Normal Operating Pressures
Outdoor Coil Entering Air Temperature
65 °F 75 °F 85 °F 95 °F 105 °F 115 °F
Suct
(psig)
Disc
(psig)
Suct
(psig)
Disc
(psig)
Suct
(psig)
Disc
(psig)
Suct
(psig)
Disc
(psig)
Suct
(psig)
Disc
(psig)
Suct
(psig)
Disc
(psig)
Circuit 1
104 244 108 282 111 324 113 370 114 420 117 474
110 248 114 286 118 328 121 375 123 425 125 479
123 258 127 296 131 339 135 385 140 436 141 491
135 280 139 310 145 352 150 400 155 452 158 507
Circuit 2
108 244 111 282 114 323 117 367 120 417 123 470
114 250 118 287 121 328 125 373 128 422 131 476
127 264 131 301 135 341 139 386 144 437 148 489
144 290 147 321 152 363 156 410 161 460 166 514
092S CAV and Staged Blower Charging Curves
60
70
80
90
100
110
120
130
100 110 120 130 140 150 160
Liquid Temperature ( °
F)
Suction Pressure (psig)
Outdoor Temperature (°F)
115°
105°
95°
85°
75°
65°
Circuit 1
Circuit 2