Page 13
ELECTRICAL/ELECTRIC HEAT DATA 12.5 TON
Model No. KCC150S4
1
Voltage - 60Hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph
Compressor 1
17.6 6.3
136 66.1
Compressor 2
22.4 10.6 7.7
3 1.2
Total
6 3 2.4
2.4 1.3 1
20
Indoor Blower
Motor
Horsepower 2 3 2 3 2 3
10.6 16.7 3.4 4.8 7.6 2.7 6.1
2
Overcurrent
Unit Only 80 80 40 40 30
80 80 40 40 40 30 30
3
Minimum
Circuit
Unit Only 60 63 30 33 22 23
62 71 30 31 34 23 24 26
ELECTRIC HEAT DATA
Electric Heat Voltage 208V 240V 208V 240V 208V 240V 480V 480V 480V 600V 600V 600V
2
Overcurrent
Unit+
Electric Heat
15 kW 80 80 80 80 40 40 30
22.5 kW 80 80 80 40 40
30 kW 100 100 110 100 60 60 40
45 kW 80 80 80 60 60 70
60 kW 80 80 70 70 70
3
Minimum
Circuit
Unit+
Electric Heat
15 kW 60 60 63 63 30 33 22 23 26
22.5 kW 78 72 81 80 40 44 31 32
30 kW 88 100 104 100 112 40 41 44
45 kW 127 131 72 74 78 60 62
60 kW 146 166 77 82 62 63 66
2
Overcurrent
Unit+
Electric Heat
15 kW 80 80 80 80 40 40 40 30 30
22.5 kW 80 80 100 40 40
30 kW 100 110 100 110 110 60 60 60
45 kW 80 80 80 60 70 70
60 kW 80 80 70 70 70
3
Minimum
Circuit
Unit+
Electric Heat
15 kW 62 62 71 71 30 31 34 23 27
22.5 kW 72 81 84 83 40 42 32 34 36
30 kW 103 107 103 41 43
45 kW 130 148 134 142 160 74 76 61 64
60 kW 138 142 161 80 84 63 64 67
ELECTRICAL ACCESSORIES
Disconnect 15 kW 54W56 54W56 54W56
22.5 kW 54W57 54W56 54W56
30 kW 54W57 54W56 54W56
45 kW Not Available 54W56 54W56
60 kW Not Available 54W56 54W56
1
2
3