Refrigerant | R-410A |
---|---|
Voltage | 208/230V |
Phase | 1 |
Cooling Capacity | 36000 BTU/h |
Sound Level | 72 dB |
Stages | Single Stage |
Displays overall physical dimensions and key measurement points of the unit.
Illustrates the location of major components within the unit.
Illustrates the location of major components within the unit.
Specifies required distances around the unit for safe operation and service access.
Outlines general guidelines and prerequisites for unit installation.
Details unit packaging contents and inspection upon receipt.
Instructions on properly supporting the unit on its base or roof structure.
Specific installation requirements for units in a downflow configuration.
Guidelines for installing units with horizontal airflow discharge.
Details on connecting supply and return air ducts to the unit.
Instructions and safety precautions for lifting and moving the unit.
Procedures for configuring the unit for horizontal airflow.
Steps for connecting the unit's condensate drainage system.
Modifying the unit for condensate drainage from the rear.
Modifying the unit for condensate drainage from the bottom.
Guidelines for connecting the gas supply line to the unit.
Detailed steps for modifying the bottom condensate drain connection.
Procedures for safely testing the gas piping for leaks.
Adjustments required for units installed at high altitudes.
Information on downloading and using the mobile service application.
Instructions for connecting the main power supply to the unit.
Wiring guidelines for the unit's control system and thermostat.
Guidance on selecting an optimal location for the room thermostat.
Configuration for operating the unit with zone sensors.
Setup for the hot gas reheat functionality for dehumidification.
Instructions for operating and testing the unit's blower.
Methods for measuring and calculating the unit's cubic feet per minute (CFM).
Specifies locations for measuring static pressure for airflow calculations.
Procedures for adjusting the unit's airflow settings via controller.
Table detailing configurable blower settings and their descriptions.
Steps to initiate and verify full load cooling operation.
Procedure for checking and adjusting the unit's refrigerant charge.
Information on the function and location of the unit's thermistor sensors.
Explains unit behavior with two-stage and three-stage thermostats/sensors.
Step-by-step instructions for starting the gas heating system.
Procedures for operating the unit's gas valve during startup.
Details on heating sequence, ignition, and limits.
Procedures for starting the optional electric heat system.
Information on the SCR controller for electric heat operation.
Instructions for operating the hot gas reheat system for dehumidification.
Procedures for verifying the correct operation of the reheat system.
Instructions for inspecting and replacing air filters.
Guidelines for inspecting and cleaning the unit's burners.
Maintenance procedures for the combustion air inducer.
Instructions for inspecting and cleaning the evaporator coil.
Procedures for cleaning the unit's condenser coil.
Maintenance for the optional bipolar ionizer system.
Installation and maintenance of the optional UVC light system.
Steps for replacing the UVC lamp annually for optimal performance.
Table of recommended fuse sizes for unit components.
Overview of controller settings and configuration options.