77
Installation and Maintenance
Service Manual
Location of
step motor
Axile bush
Horizontal louver
Right filter
Front
case
Groove
Left filter
Front panel
Open the front panel. Push the left and
thegroove on the front case. Then remove
Push out the axile bush on horizontal louver,
Bend the horizontal louver with hand and
then separate the horizontal louver from the
crank shaft of step motor to remove it.
Separate the panel rotation shaft from
removes the front panel.
Screw off the 2 screws that are locking the
display board.
2.Remove horizontal louver
3.Remove panel and display
Screws
D2 display
A3 display
Front panel C2 display
Panel rotation
Groove
LI024CI-180P432
LI024HI-180P432